Definitions; Elbow Vent Length Values - Napoleon GD36NTR Installation And Operating Instructions Manual

Natural gas model/propane gas model
Table of Contents

Advertisement

2.6

DEFINITIONS

For the following symbols used in the venting calculations and examples are:
> - greater than
> - equal to or greater than
< - less than
< - equal to or less than
H
- total of both horizontal vent lengths (Hr) and offsets (Ho) in feet
T
H
- combined horizontal vent lengths in feet
R
H
- offset factor: .03 (total degrees of offset - 90°*) in feet
O
V
- combined vertical vent lengths in feet
T
2.7

ELBOW VENT LENGTH VALUES

FEET INCHES
0.03
15°
0.45
30°
0.9
45°
1.35
90°*
2.7
* The first 90° offset has a zero value and is shown in the formula as - 90°
0.5
6.0
11.0
16.0
32.0
15
14.1
15.1