VENTING APPLICATION FLOW CHART

Horizontal Termination
Vertical rise is equal
to or greater than the
horizontal run
Horizontal run +
vertical rise to
maximum of 40 feet
Horizontal Termination
Vertical rise is equal
to or greater than the
horizontal run
Horizontal run +
vertical rise to
maximum of 40 feet
W415-0210 / S /03.10.09
TOP EXIT
Vertical rise
is less than
horizontal run
Horizontal run +
vertical rise to
maximum of 24.75
feet
4.2 times the
vertical rise equal
to or greater than
the horizontal run
REAR EXIT
Vertical rise
is less than
horizontal run
Horizontal run +
vertical rise to
maximum of 24.75
feet
3.5 times the
vertical rise equal
to or greater than
the horizontal run
Vertical Termination
Vertical rise is equal
to or greater than
the horizontal run
Horizontal run +
vertical rise to
maximum of 40 feet
Vertical Termination
Vertical rise is equal
to or greater than
the horizontal run
Horizontal run +
vertical rise to
maximum of 40 feet
Vertical rise is less
than horizontal run
Horizontal run +
vertical rise to
maximum of 40
feet
3 times the
vertical rise equal
to or greater than
the horizontal run
13.1
Vertical rise is less
than horizontal run
Horizontal run +
vertical rise to
maximum of 40
feet
3 times the
vertical rise equal
to or greater than
the horizontal run
13.2