4.0 BLOwEr INSTALLATION

4.0.1 Ensure that the access cover plate has been installed.
4.0.2 Remove the on/off switch bracket and the cover plate
below it. The cover plate may now be discarded.
4.0.3 Decide which side of the blower housing you prefer the
on/off switch to be located on.
4.0.4 Remove the 2 screws from the top outer edge of the rear
heater panel. The housing is mounted using these two
holes, as well as two other holes located in the rear panel.
4.0.5 Mount and secure the blower housing using 4 screws.
Ensure that the on/off switch wires pass through the
appropriate slot located on either side of the blower
housing.
4.0.6 Remove the 2 screws from the side of the blower housing that
you want the switch to be located on and re-secure the on/off
switch.
because the blower is thermally activated, when turned on, it will automatically start
approximately 15-30 minutes after lighting the heater and will run for approximately
30-45 minutes after the heater has been turned off. Use of the fan increases the
output of heat.
Drywall dust will penetrate into the blower bearings, causing
irreparable damage. Care must be taken to prevent drywall
dust from coming into contact with the blower or its
compartment. Any damage resulting from this condition is not
covered by the warranty policy.
W415-0204 / F / 10.23.08
ON/Off
swITCh
braCkET
COvEr
PlaTE
aCCEss PlaTE
fIgurE 4.0.1
fIgurE 4.0.5
slOT
rEmOvEd sCrEws
fIgurE 4.0.6