5.0 ELECTRICAL INFORMATION

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED
SERVICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE
RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE
APPLIANCE WALL SWITCH. INCORRECT WIRING WILL DAMAGE CONTROLS.
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1 CANADIAN
ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI/NFPA NO. 70 IN
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT,
5.1

WIRING DIAGRAM (IR3)

This appliance comes equipped with a battery pack. Install 4 AA batteries into the holder that is connected to
the wire harness. Place near the front of the appliance for ease of changing batteries.
DC BATTERY PACK
-
+
+
-
!
ELECTRICAL CIRCUIT.
THE UNITED STATES.
WITH THE GLASS DOOR OPENED OR REMOVED.
ON / OFF
SWITCH
(SUPPLIED
WITH TRIM)
ON / OFF
DISCONNECT THESE
CONNECTORS TO THE
ON/OFF SWITCH AND
CONNECT TO
OPTIONAL
THERMOSTAT OR
REMOTE .
WARNING
VALVE
GROUND
EYELET
GROUND
69.2
GREEN
ORANGE
VALVE
ELECTRONIC
IPI BOARD
DFC
W415-1033 / A / 10.12.11