WARNING
Turn off the appliance completely and let cool before servicing. Only a qualified service person should service
and repair this electric appliance.
It is necessary to hard-wire this appliance. A qualified electrician must wire the appliance directly to the household
wiring. The wire and power supply breaker must be rated for 120V, minimum 15 amps.
This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local
codes, with the latest edition of the National Electrical Code ANSI/NFPA 70 in the United States or the Canadian
Electrical Code CSA C22.1 in Canada.
Before hardwiring the appliance, remove the junction box control cover by removing the fasteners as shown.
1. Locate the desired 2 conductor or 3 conductor wire cable to the top right side of the enclosure for the
hard-wiring installation based on the desired 120V or 240V heat output capability.
2. With appliance in the rough-in framing, insert it far enough into the enclosure to locate the supply wires
to the terminal block.
3. Insert the wires from your home through the junction box cover plate with the strain relief (supplied) and
locate the wires to the specified terminal block location based on desired voltage selection.

3.0 electrical information