Table of Contents

Advertisement

Available languages

Available languages

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
CONFORMS TO AMERICAN NATIONAL STANDARDS: ANSI Z21.50, CERTIFIED TO CANADIAN CSA 2.22 FOR VENTED GAS FIREPLACES.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

SAFETY INFORMATION

WARNING
!
If the information in these instructions
are not followed exactly, a fi re or
explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certifi ed kit is used.
Decorative Product: Not for use as a heating appliance.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
$10.00
INSTALLATION AND
OPERATING INSTRUCTIONS
BARRIER
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
XIR3N

NATURAL GAS

XIR3P
PROPANE
WARNING
!
HOT GLASS WILL CAUSE
DO NOT TOUCH GLASS UNTIL
NEVER ALLOW CHILDREN TO
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with the appliance and
shall be installed.
BURNS.
COOLED.
TOUCH GLASS.
C E R T I F I E D
1.36D
W415-1343 / 10.07.14
EN
FR
PG
45

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon XIR3N

  • Page 1: Safety Information

    BARRIER C E R T I F I E D Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com $10.00...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS NOTE: The camera icon indicates video tutorials are available as additional reference, visit http://www.napoleonfireplaces.com/category/product-support/support-centre/ INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS MINIMUM CLEARANCE TO COMBUSTIBLES GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION INSTALLATION LEVELLING THE APPLIANCE CHIMNEY CONNECTION GAS INSTALLATION FINISHING MINIMUM COMBUSTIBLE MANTEL CLEARANCES SAFETY SCREEN &...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW Venting, see “INSTALLATION - CHIMNEY CONNECTION” section. Rating Plate, see “RATING PLATE INFORMATION” section. Batteries, see “BATTERY INSTALLATION” section. Receiver, see “PROGRAMMING” section. Logs, see “FINISHING - LOG PLACEMENT” section. Batteries must be disposed of according to the local laws and regulations. Some batteries may be recycled, and may be accepted for disposal at your local recycling center.
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi...
  • Page 5: Dimensions

    DIMENSIONS 22 7/8" 21" 581mm 533mm 17 1/2" SAFETY BARRIER 20 1/2" 13 1/4" 9 1/2" 445mm 521mm 337mm 241mm 29 5/8" 12" 753mm 305mm 17 1/2" 445mm MINIMUM CLEARANCE TO COMBUSTIBLES This appliance must be recessed into a vented noncombustible wood-burning appliance (prefabricated or masonry) only.
  • Page 6: General Information

    • A Carbon Monoxide detector is required in all rooms containing gas fi red appliances. • The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product. We suggest that our gas The installation must conform with local codes or, in hearth products be installed absence of local codes, the National Gas and Propane...
  • Page 7: Rating Plate Information

    SOUFFLERIE OPTIONELLEGZ550-KT, GD65. SERIAL NUMBER/NO. DE SERIE: XIR3/CXIR3 24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA ROAD, BARRIE. ONTARIO L4M 0G8 CANA W385-1972 / A INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to the model, venting and gas type of the appliance.
  • Page 8: Installation

    3.0 INSTALLATION WARNING RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE. Clean out ashes from the inside of the wood-burning appliance. Make sure that the chimney and wood-burning appliance are in a clean and sound condition and constructed of non-combustible materials. If necessary have any repair work done by a qualifi...
  • Page 9: Chimney Connection

    CHIMNEY CONNECTION Chimney installation must conform to both national and local code requirements. The chimney must be lined with one 3" (76mm) diameter liner for intake and one 3" (76mm) diameter liner for exhaust. The minimum and maximum vent lengths are 10 and 35 feet (3 and 10 meters) respectively. Recommended kits come in 3 lengths: 2-3"...
  • Page 10: Gas Installation

    GAS INSTALLATION WARNING RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 11: Minimum Combustible Mantel Clearances

    MINIMUM COMBUSTIBLE MANTEL CLEARANCES WARNING RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE CLEARLY MAINTAINED.
  • Page 12: Safety Screen & Door Removal / Installation

    SAFETY SCREEN & DOOR REMOVAL / INSTALLATION WARNING GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. THE DOOR LATCHES ARE PART OF A SAFETY SYSTEM AND MUST BE PROPERLY ENGAGED. DO NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED. FACING AND/OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR OPENINGS, LOUVRES OPENINGS, OPERATION OF LOUVRES OR DOORS OR ACCESS FOR SERVICE.
  • Page 13: Log Placement

    76.1A PHAZER logs and glowing embers exclusive to Napoleon, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect. Log colours may vary. During the initial use of the appliance, the colours will become more uniform as colour pigments burn in during the heat activated curing process.
  • Page 14: Glowing Embers

    OPTIONAL ROCK PLACEMENT WARNING REAL ROCKS MUST NOT BE USED IN THIS APPLIANCE. HEAT WILL CAUSE THEM TO EXPLODE Before beginning with the installation, remove the door and all burner media from the appliance including logs and charcoal strips. Retain the glowing embers. A.
  • Page 15: Battery Installation

    BATTERY INSTALLATION 4 AA batteries must be installed into the receiver before operation is possible in the XIR3. The receiver is located in the bottom left corner of the appliance. RECEIVER If receiver removal is necessary, remove the left access panel from the front of the appliance.
  • Page 16: Electrical Information

    5.0 ELECTRICAL INFORMATION WARNING DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED SERVICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE ELECTRICAL CIRCUIT. RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE APPLIANCE WALL SWITCH.
  • Page 17: Operation

    6.0 OPERATION WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 18: Xir3 Operation

    XIR3 OPERATION WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 19: Hand Held Remote Operations

    6.2.3 HAND HELD REMOTE OPERATIONS Press the ON/OFF key on the transmitter. The transmitter display will show all active icons on the screen. A single “beep” from the receiver will confi rm reception of the command. BLUE LCD DISPLAY ON/OFF KEY TEMPERATURE KEY UP/DOWN ARROW KEY...
  • Page 20: Flame Height

    6.2.7 FLAME HEIGHT The remote control has six (6) fl ame levels. With the °F °F system on and the fl ame level at the maximum, press the Down Arrow Key once and it will reduce the fl ame height by one step until the fl ame is turned off. The Up Arrow Key will increase the fl...
  • Page 21: Low Battery / Manual Bypass

    6.2.10 LOW BATTERY / MANUAL BYPASS The life span of the remote batteries depends on various factors: quality of the °F batteries, the number of ignitions, etc. When the transmitter batteries are low, a Battery Icon will appear on the LCD display before all battery power is lost.
  • Page 22: Timed Blower

    6.2.14 TIMED BLOWER Your remote system may have a built in timer (in thermostat mode) that enables the blower (if equipped) to cycle on and off automatically when the burner turns on and off. With the remote control fan speed preset at the preferred speed, the blower will come on approximately 5 minutes after the main burner comes on and will shut off approximately 12 minutes after the burner shuts off.
  • Page 23: Adjustments

    7.0 ADJUSTMENTS PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. Check Pressure Readings: Inlet pressure can be checked by turning screw (A) counter- clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point.
  • Page 24: Flame Characteristics

    FLAME CHARACTERISTICS It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustration provided. If any fl ames appear abnormal call a service person. PILOT ELECTRODE BURNER 3/8” - 1/2” (9.5mm - 12.7mm) FLAME SENSOR FLAME MUST ENVELOP...
  • Page 25: Annual Maintenance

    / or blemishes may result. TO TOUCH GLASS. This appliance is factory equipped with 5mm ceramic glass. Use only replacement glass available from your Napoleon® dealer. DO NOT SUBSTITUTE MATERIALS. 5.5.1 CARE OF PLATED PARTS If the appliance is equipped with plated parts, you must clean fi ngerprints or other marks from the plated surfaces before operating the appliance for the fi...
  • Page 26: Door Glass Replacement

    DOOR GLASS REPLACEMENT WARNING DO NOT USE SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
  • Page 27: Burner Removal

    BURNER REMOVAL Remove the glass door, see "DOOR REMOVAL AND INSTALLATION" section. Remove the logs, see "FINISHING" section. Remove the 5 screws that secure Remove the 4 screws holding the the rear log support in place. Lift the rear burner tube and lift it up and support out.
  • Page 28: Fcm Replacement

    FCM REPLACEMENT WARNING TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. THE APPLIANCE MAY BE HOT. DO NOT SERVICE APPLIANCE UNTIL IT HAS COOLED. To access the fan control module, you must fi rst pull out the appliance, allowing enough room to access the left access plate.
  • Page 29: Valve Train Replacement

    VALVE TRAIN REPLACEMENT Remove the glass door. See "DOOR REMOVAL AND INSTALLATION" section. Remove the burners, see "BURNER REMOVAL" section. Remove the 14 screws holding the valve train in place. NOTE: A new gasket may be required when reinstalling the valve train assembly. Contact your local authorized dealer/distributor.
  • Page 30: Replacements

    9.0 REPLACEMENTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor. WARNING FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM. FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS When ordering replacement parts always give the following information:...
  • Page 31: Overview

    W415-1343 / 10.07.14...
  • Page 32 W415-1343 / 10.07.14...
  • Page 33: Accessories

    W415-1343 / 10.07.14...
  • Page 34 W415-1343 / 10.07.14...
  • Page 35: Valve Train Assembly

    W415-1343 / 10.07.14...
  • Page 36: Firebox Top Assembly

    W415-1343 / 10.07.14...
  • Page 37: Troubleshooting

    14.0 TROUBLESHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 38 White / grey fi lm Sulphur from fuel is being Clean the glass with a recommended gas fi replace forms. deposited on glass, logs glass cleaner. DO NOT CLEAN GLASS WHEN HOT. or combustion chamber If deposits are not cleaned off regularly, the glass surfaces.
  • Page 39 SYMPTOM PROBLEM TEST SOLUTION Pilot sparks but Gas supply. Verify that the incoming gas line ball valve is “Open”. will not light. Verify that the inlet pressure reading is within acceptable limits, inlet pressures must not exceed 14” W.C. (34.9mb). Module is not grounded.
  • Page 40: Warranty

    All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim. During the fi rst 10 years NAPOLEON® will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge. From 10 years to life, NAPOLEON®...
  • Page 41: Service History

    16.0 SERVICE HISTORY W415-1343 / 10.07.14...
  • Page 42: Notes

    17.0 NOTES 44.1 W415-1343 / 10.07.14...
  • Page 43 44.1 W415-1343 / 10.07.14...
  • Page 44 Fireplace Inserts • Charcoal Grills • Gas Fireplaces • Waterfalls • Wood Stoves Heating & Cooling • Electric Fireplaces • Outdoor Fireplaces • Gourmet Grills 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8...
  • Page 45 N° DE MODÈLE C E R T I F I E D Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 705-721-1212 • Télécopieur 705-722-6031 • www.napoleonfoyers.com • ask@napoleon.on.ca 10,00$ 1.36D...
  • Page 46 TABLE DES MATIÈRES NOTE: L'icône du camera indique que les vidéos sont disponibles comme une référence supplémentaire, visitez http://www.napoleonfireplaces.com/category/product-support/support-centre/ VUE D’ENSEMBLE DE L’INSTALLATION INTRODUCTION DIMENSIONS DÉGAGEMENTS MINIMAUX AUX MATÉRIAUX COMBUSTIBLES INSTRUCTIONS GÉNÉRALES INFORMATION GÉNÉRALE PLAQUE D'HOMOLOGATION INSTALLATION MISE À NIVEAU DE L'ENCASTRÉ INSTALLATION DE LA CHEMINÉE BRANCHEMENT DU GAZ FINITIONS...
  • Page 47: Vue D'ensemble De L'installation

    1.0 VUE D’ENSEMBLE DE L’INSTALLATION Évacuation, voir la section « INSTALLATION - INSTALLATION DE LA CHEMINÉE ». Plaque d’homologation, voir la section « INFORMATION SUR LA PLAQUE D’HOMOLOGATION ». Bûches, voir la section Piles, voir la section «INSTALLATION DES « FINITIONS - DISPOSITION PILES (IR3 Seulement).
  • Page 48: Introduction

    2.0 INTRODUCTION AVERTISSEMENT • CET APPAREIL EST CHAUD LORSQU’IL FONCTIONNE ET PEUT CAUSER DE GRAVES BRÛLURES EN CAS DE CONTACT. • TOUTE MODIFICATION APPORTÉE À CET APPAREIL OU AUX CONTRÔLES PEUT ÊTRE DANGEREUX ET EST INTERDIT. • Ne faites pas fonctionner l’appareil avant d’avoir lu et compris les instructions d’opération. Omettre d’utiliser l’appareil selon les instructions d’opération pourrait causer un incendie ou des blessures.
  • Page 49: Dimensions

    DIMENSIONS 22 7/8" 21" 581mm 533mm 17 1/2" SAFETY BARRIER ÉCRAN DE PROTECTION 20 1/2" 13 1/4" 9 1/2" 445mm 521mm 337mm 241mm 29 5/8" 12" 753mm 305mm 17 1/2" 445mm DÉGAGEMENTS MINIMAUX AUX MATÉRIAUX COMBUSTIBLES Cet appareil ne doit être encastré que dans un foyer à bois ventilé incombustible (préfabriqué ou en maçonnerie). L'appareil dans lequel l’encastré...
  • Page 50: Information Générale

    • Un détecteur de monoxyde de carbone est requis dans toutes les pièces contenant des appareils alimentés au gaz. • L’appareil n’est pas approuvé pour installation dans une chambre à coucher ou une salle de bain à moins d’être un appareil avec une chambre de combustion scellée à...
  • Page 51: Plaque D'homologation

    WOLF STEEL LTD. SOUFFLERIE OPTIONELLEGZ550-KT, GD65. SERIAL NUMBER/NO. DE SERIE: XIR3/CXIR3 24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA NTARIO L4M 0G8 CA W385-1972 / A INSTALLATEUR : Il est de votre responsabilité de cocher les cases appropriées sur la plaque d'homologation correspondant au modèle, au type d'évacuation et au type de gaz de l'appareil.
  • Page 52: Installation

    3.0 INSTALLATION AVERTISSEMENT RISQUE D’INCENDIE CONSERVEZ LES DÉGAGEMENTS NÉCESSAIRES AU CONDUIT D’EVENT ET À L’APPAREIL. Retirez les cendres de l’appareil de chauffage au bois. Assurez-vous que la cheminée et l’appareil de chauffage au bois sont propres et en bon état et qu’ils sont construits avec des matériaux incombustibles. Si nécessaire, faites faire les travaux de réparation par une personne qualifi...
  • Page 53: Installation De La Cheminée

    INSTALLATION DE LA CHEMINÉE L’installation de la cheminée doit être conforme aux normes des codes nationaux et locaux. La cheminée doit être munie d'un conduit de 2" (51mm) ou 3" (76mm) de diamètre pour la prise d'air et d'un conduit de 3" (76mm) de diamètre pour l'évacuation.
  • Page 54: Branchement Du Gaz

    BRANCHEMENT DU GAZ AVERTISSEMENT RISQUE D'INCENDIE, D'EXPLOSION OU D'ASPHYXIE. ASSUREZ-VOUS QU'IL N'Y AIT AUCUNE SOURCE D'ALLUMAGE COMME DES ÉTINCELLES OU UNE FLAMME NUE. SOUTENEZ LE CONTRÔLE DU GAZ LORSQUE VOUS ATTACHEZ LE TUYAU POUR ÉVITER DE PLIER LA CON- DUITE DE GAZ. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 55: Finitions

    4.0 FINITIONS AVERTISSEMENT RISQUE D’INCENDIE! N’OBSTRUEZ JAMAIS L’OUVERTURE SUR LE DEVANT DE L’APPAREIL. LA FAÇADE DE L’APPAREIL DOIT ÊTRE FAITE DE MATÉRIAUX INCOMBUSTIBLES COMME DE LA BRIQUE, DU MARBRE, DU GRANITE, ETC., À CONDITION QUE CES MATÉRIAUX NE SE TROUVENT PAS EN DEÇÀ...
  • Page 56: Enlèvement Et Installation De La Porte

    ENLÈVEMENT ET INSTALLATION DE LA PORTE AVERTISSEMENT LA VITRE PEUT ÊTRE CHAUDE, NE TOUCHEZ PAS LA VITRE JUSQU’À CE QU’ELLE AIT REFROIDI. LES LOQUETS DE PORTE FONT PARTIE D'UN DISPOSITIF DE SÉCURITÉ ET DOIVENT ÊTRE ADÉQUATEMENT VERROUILLÉS. NE FAITES PAS FONCTIONNER L’APPAREIL LORSQUE LES LOQUETS SONT DÉVERROUILLÉS. LES MATÉRIAUX DE FAÇADE ET DE FINITION NE DOIVENT PAS NUIRE À...
  • Page 57: Disposition Des Bûches

    DISPOSITION DES BÛCHES AVERTISSEMENT OMETTRE DE POSITIONNER LES BÛCHES CONFORMÉMENT AUX SCHÉMAS OU OMETTRE D’UTILISER UNIQUEMENT DES BÛCHES SPÉCIFIQUEMENT APPROUVÉES POUR CET APPAREIL PEUT CAUSER DES DOMMAGES MATÉRIELS OU DES BLESSURES CORPORELLES. LES BÛCHES DOIVENT ÊTRE PLACÉES CORRECTEMENT À L’INTÉRIEUR DE L’APPAREIL. NE CHANGEZ PAS LA POSITION DES BÛCHES CAR L’APPAREIL RISQUE DE NE PAS FONCTIONNER ADÉQUATEMENT ET UN RETARD D’ALLUMAGE RISQUE DE SE PRODUIRE.
  • Page 58: Placement De La Roches Optionnelle

    PLACEMENT DE LA ROCHES OPTIONNELLE AVERTISSEMENT NE PAS UTILISER DE VRAIES ROCHES DANS CET APPAREIL. LA CHALEUR LES FERA EXPLOSER. Avant de commencer l'installation, retirez la porte, les bûches, les bandes de charbon de bois et les braises incandescentes de l'appareil. Conservez les braises incandescentes. A.
  • Page 59: Installation Des Piles

    INSTALLATION DES PILES Pour que le XIR3 soit fonctionnel, vous devez installer 4 piles AA dans le récepteur. Le récepteur est situé dans le coin inférieur gauche de l'appareil. RÉCEPTEUR Si vous devez enlever le récepteur, retirez le panneau d'accès gauche du devant de l'appareil.
  • Page 60: Information Électrique

    5.0 INFORMATION ÉLECTRIQUE AVERTISSEMENT N’UTILISEZ PAS CE FOYER SI UNE PARTIE QUELCONQUE A ÉTÉ SUBMERGÉE. CONTACTEZ IMMÉDIATEMENT UN TECHNICIEN DE SERVICE QUALIFIÉ POUR INSPECTER L’APPAREIL POUR DES DOMMAGES AU CIRCUIT ÉLECTRIQUE. RISQUE DE CHOCS ÉLECTRIQUES OU D’EXPLOSION. NE BRANCHEZ PAS LE 110 V À LA SOUPAPE OU À...
  • Page 61: Fonctionnement

    6.0 FONCTIONNEMENT AVERTISSEMENT SI CES INSTRUCTIONS NE SONT PAS SUIVIES À LA LETTRE, UN INCENDIE OU UNE EXPLOSION POURRAIENT S’ENSUIVRE, CAUSANT DES DOMMAGES MATÉRIELS,DES BLESSURES CORPORELLES OU DES PERTES DE VIE. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 62: Xir3 Fonctionnement

    XIR3 FONCTIONNEMENT AVERTISSEMENT SI CES INSTRUCTIONS NE SONT PAS SUIVIES À LA LETTRE, UN INCENDIE OU UNE EXPLOSION POURRAIENT S’ENSUIVRE, CAUSANT DES DOMMAGES MATÉRIELS,DES BLESSURES CORPORELLES OU DES PERTES DE VIE. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 63: Fonctionement De La Télécommande

    6.2.3 FONCTIONEMENT DE LA TÉLÉCOMMANDE Appuyez sur la touche « ON/OFF » de la télécommande. L’affi cheur de la télécommande affi chera toutes les icônes actives à l’écran. Un bip unique du récepteur confi rmera la AFFICHEUR ACL BLEU réception de la commande. TOUCHE ON/OFF TOUCHE TEMPÉRATURE TOUCHE HAUT/BAS...
  • Page 64: Hauteur De La Flamme

    6.2.7 HAUTEUR DE LA FLAMME La télécommande comporte six (6) niveaux de fl ammes. °F °F Avec le système en marche et le niveau de la fl amme au maximum, appuyez une fois sur la touche bas et cela réduira la hauteur de la fl amme d’un niveau jusqu’à...
  • Page 65: Piles Faibles / Dérivation Manuelle

    6.2.10 PILES FAIBLES / DÉRIVATION MANUELLE La durée de vie des piles de la télécommande dépend de plusieurs facteurs : la °F qualité des piles, le nombre d’allumage de l’appareil, le nombre de changements du point de réglage du thermostat, etc. Dès que les piles de la télécommande sont faibles, l’écran ACL affi...
  • Page 66: Minuterie De Soufflerie

    6.2.14 MINUTERIE DE SOUFFLERIE Votre télécommande est munie d’une minuterie intégrée (en mode thermostat) qui permet d’allumer et d’éteindre la souffl erie automatiquement (si équipé) lorsque le brûleur s’allume et s’éteint. La vitesse de la souffl erie étant déjà réglée sur la télécommande à la vitesse désirée, la souffl erie se mettra en marche environ 5 minutes après l’allumage du brûleur et s’arrêtera environ 12 minutes après la fermeture du brûleur.
  • Page 67: Réglages

    7.0 RÉGLAGES RÉGLAGE DE LA VEILLEUSE Ajustez la vis de la veilleuse pour obtenir une fl amme de taille normale. Tournez vers la droite pour réduire l’apport de gaz. VÉRIFIER LA PRESSION : Pour vérifi er la pression d’arrivée, tournez la vis (A) vers la gauche deux à...
  • Page 68: Caractéristiques De La Flamme

    CARACTÉRISTIQUES DE LA FLAMME Il est important d’effectuer périodiquement une inspection visuelle de la fl amme de la veilleuse et du brûleur. Comparez-les à ces illustrations. Si des fl ammes paraissent anormales, contactez un technicien de service. ÉLECTRODE VEILLEUSE 3/8” - 1/2” (9,5mm - 12,7mm) LA SONDE DE FLAMME...
  • Page 69: Entretien

    8.0 ENTRETIEN AVERTISSEMENT COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL. L’APPAREIL PEUT ÊTRE CHAUD. ATTENDEZ QU’IL SOIT REFROIDI AVANT D’EN FAIRE L’ENTRETIEN. N’UTILISEZ PAS DE PRODUITS ABRASIFS. NE PEINTURE PAS L’ASSEMBLAGE DU VEILLEUSE. ATTENTION : Lors de l’entretien des contrôles, assurez-vous d’identifi...
  • Page 70: Entretien Annuel

    ENTRETIEN ANNUEL AVERTISSEMENT LE CAISSON DEVIENT TRÈS CHAUD LORS DU FONCTIONNEMENT. LAISSEZ L’APPAREIL SE REFROIDIR COMPLÈTEMENT OU PORTEZ DES GANTS ANTICHALEUR AVANT D’EFFECTUER L’ENTRETIEN. NE JAMAIS ASPIRER DES BRAISES QUI SONT CHAUDES. NE PEINTUREZ PAS L’ASSEMBLAGE DE LA VEILLEUSE. • Cet appareil nécessite un entretien qui devra être effectué...
  • Page 71: Soins Des Pièces Plaquées

    SOINS DES PIÈCES PLAQUÉES Si l’appareil est muni de pièces plaquées, vous devez enlever toutes traces de doigts ou autres marques des surfaces plaquées avant d’allumer l’appareil pour la première fois. Utilisez un nettoyant à vitres ou du vinaigre et un linge pour nettoyer. Si la surface plaquée n’est pas bien nettoyée avant le premier allumage de l’appareil, elle risque de rester marquée en permanence.
  • Page 72: Enlèvement Du Brûleur

    ENLÈVEMENT DU BRÛLEUR Enlevez la porte vitrée, voir la section « ENLÈVEMENT ET INSTALLATION DE LA PORTE ». Retirez les bûches, voir la section « FINITIONS ». Retirez les 5 vis servant à fi xer le Retirer les 4 vis servant à fi xer le support à...
  • Page 73: Remplacement Du Module Souffleur

    REMPLACEMENT DU MODULE SOUFFLEUR AVERTISSEMENT COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL. L’APPAREIL PEUT ÊTRE CHAUD. ATTENDEZ QU’IL SOIT REFROIDI AVANT D’EN FAIRE L’ENTRETIEN. Pour accéder au module de la souffl erie, vous devez d'abord sortir l'appareil afi...
  • Page 74: Replacement De L'assemblage De La Soupape

    REPLACEMENT DE L'ASSEMBLAGE DE LA SOUPAPE Retirez la porte vitrée. Voir la section « ENLÈVEMENT ET INSTALLATION DE LA PORTE ». Retirez les brûleurs, voir la section « ENLÈVEMENT DU BRÛLEUR ». Retirez les 14 vis servant à fi xer l’assemblage de la soupape. NOTE : Il est possible qu'un nouveau joint d'étanchéité...
  • Page 75: Rechanges

    9.0 RECHANGES Contactez votre détaillant ou le fabricant pour les questions concernant les prix et la disponibilité des pièces de rechange. Normalement, toutes les pièces peuvent être commandées chez votre détaillant autorisé. POUR UN REMPLACEMENT DE PIÈCE SOUS GARANTIE, UNE PHOTOCOPIE DE LA FACTURE ORIGI- NALE SERA REQUISE AFIN DE POUVOIR HONORER LA DEMANDE.
  • Page 76: Vue D'ensemble

    W415-1343 / 10.08.14...
  • Page 77 W415-1343 / 10.08.14...
  • Page 78: Accessories

    W415-1343 / 10.08.14...
  • Page 79 W415-1343 / 10.08.14...
  • Page 80: L'assemblage De La Soupape

    W415-1343 / 10.08.14...
  • Page 81: L'assemblage Dessus De Foyer

    W415-1343 / 10.08.14...
  • Page 82: Guide De Dépannage

    14.0 GUIDE DE DÉPANNAGE MAINTENANCE MAINTENANCE AVERTISSEMENT MAINTENANCE ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL.
  • Page 83 SYMPTÔME PROBLÈME SOLUTIONS On détecte l’odeur L’appareil refoule les Vérifi ez tous les joints scellés de la porte. des gaz de gaz de combustion dans Vérifi ez si la cheminée ne serait pas bloquée. combustion dans la pièce. Vérifi ez que les conduits d’évents sont installés correctement. la pièce;...
  • Page 84 SYMPTÔME PROBLÈME SOLUTIONS Étincelle à la Alimentation en gaz. Vérifi ez si la soupape à bille de la conduite d’arrivée veilleuse mais du gaz est « Ouverte ». Vérifi ez si la pression celle-ci ne d’arrivée est dans les limites acceptables. La s’allume pas.
  • Page 85: Garantie

    15.0 GARANTIE Les produits Napoléon® sont fabriqués conformément aux normes strictes du Certifi cat d’Assurance de la Qualité mondialement reconnu ISO 9001 : 2008. Les produits Napoléon® sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifi...
  • Page 86: Historique D'entretien

    16.0 HISTORIQUE D’ENTRETIEN 43.1 W415-1343 / 10.08.14...
  • Page 87: Notes

    17.0 NOTES 44.1 W415-1343 / 10.08.14...
  • Page 88 Poêles à bois • Produits HVAC • Foyers électriques • Foyers extérieurs • Grils à gaz de qualité 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8...

This manual is also suitable for:

Xir3p

Table of Contents