24
6.2.14
TIMED BLOWER
Your remote system may have a built in timer (in thermostat mode) that enables the blower to cycle on and
off automatically when the burner turns on and off. With the remote control fan speed preset at the preferred
speed, the blower will come on approximately 5 minutes after the main burner comes on and will shut off
approximately 12 minutes after the burner shuts off.
This time delay is designed to maximize the blower distribution of heated air.
If at any time the burner re-ignites before the twelve minutes are over, the fan will continue to run.
NOTE: At any time in the sequence, the blower can be manually turned on/off using the remote
control.
6.3
IR3 OPERATION
6.3.1
ON/OFF SWITCH LOCATION
The ON/OFF switch is located in the top right side of the surround. Turn it on to
activate the fl ame.
6.3.2 VALVE MANUAL HIGH/LOW ADJUSTMENT
The IR3 is equipped with a manual HIGH/LOW valve which is located in the bottom right corner.
Flame adjustment should be made while the appliance is cool. To adjust the flame to high, turn the knob
counter-clockwise, to adjust the flame to low, turn the knob clockwise.
W415-1033 / A / 10.12.11
35.19A