Commissioning
7.3 Description of OSD menu
Main menu
48
Function
Signal adjustment
Switch loop
Tolerance factor
Signal (only for analog
signal)
Adjustment/range
1 ... 20
Default: 1
1 ... 20
Default: 1
RGB
Monochrome
Default:
RGB
(for SCD19102)
Monochrome
(for
)
SMD19102
Instruction Manual, 05/2008, A5E01588521A-002
Description
The following four
parameters are of relevance
for this tool:
H-frequency
V-frequency
V-total
Interlaced/non Interlaced
If one of these parameters
changes, the display treats it
as a timing change and
initiates resynchronization
via an "Auto in progress". To
prevent this from happening
as a result of each and every
minor signal disturbance, the
value representing the
permissible number of faulty
or changed frames must be
increased in the case of
unstable signal sources.
Disadvantage:
The higher the tab setting,
the longer it will take for a
desired timing change to
occur (delayed by a number
of milliseconds).
This tool only considers the
H and V frequencies.
An increase in the tab value
results in a larger tolerance
band being defined. Minor
frequency fluctuations within
this range will not result in
resynchronization ("Auto in
progress").
Switch over signal between
b/w and color operation
If a monochrome signal
arrives, it is green on the
color display.
To obtain correct b/w
images, set the "Signal"
parameter to
monochrome.