Design
D Three-phase 400-VAC Input Model
3G3EV model
Output
A4002(M)-CUE
0.2 kW
A4004(M)-CUE
0.4 kW
A4007(M)-CUE
0.75 kW
A4015(M)-CUE
1.5 kW

3-1-2 Installation Conditions

H Installation Site
• Install the Inverter under the following conditions:
Ambient temperature for operation: –10°C to 50°C
Humidity: 90% RH or less (non-condensing)
• Install the Inverter in a clean location free from oil mist and dust. Alternatively, install it in a totally en-
closed panel that is completely shielded from suspended dust.
• When installing or operating the Inverter, always take special care so that metal powder, oil, water, or
other foreign matter do not get in the Inverter.
• Do not install the Inverter on inflammables such as wood.
H Direction of Installation
• Install the Inverter on a vertical surface so that the characters on the nameplate are oriented upward.
H Installation Space
• When installing the Inverter, always provide the following installation space to allow normal heat dis-
sipation from the Inverter:
3-4
W
H
108
128
130
W= 30 mm min.
D
W1
96
92
110
140
170
118
100 mm min.
Air
Side
Air
100 mm min.
Chapter 3
H1
Weight (kg)
118
Approx. 1.0
Approx. 1.0
Approx. 1.5
Approx. 2.0