Warnings - Rinnai V2532FFU Series Operation & Installation Manual

Residential and commercial indoor unit
Table of Contents

Advertisement

I N S TA L L E R ' S I N S TA L L AT I O N I N S T R U C T I O N S
1) Read the safety issues completely before installing the Rinnai Water Heater.
2) This water heater is suitable for residential water (potable) heating ONLY.
DO NOT use this water heater for space heating, combination space heating/
domestic water heating, or commercial water heating applications.
3) The Rinnai Water Heater is not suitable for use in pool or spa applications.
4) This unit is designed to be installed indoors using the proper vent piping to
exhaust by-products of combustion to the outside environment. Contact your
dealer or Rinnai for proper vent kits. DO NOT operate this unit without vent
piping connected. Exhaust gasses must be expelled outside the home. All
pipe joints shall be taped to help prevent leakage around joints. (Aluminum
tape is recommended.)
5) Maintain proper space around the unit for proper servicing and operation.
Minimum clearances from combustible materials are listed below.
6) Installer must install a Pressure relief valve. Pipe pressure relief discharge to a
drain or outside environment (see page 41 for pressure relief valve rating).
7) The appliance should be located in an area where leakage of the unit or
connections will not result in damage to the area adjacent to the appliance or
to lower fl oors of the structure. When such locations cannot be avoided, it is
recommended that a suitable drain pan, adequately drained, be installed under
the appliance. The pan must not restrict combustion air fl ow.
Rinnai America
-Warnings- (Residential Unit)
This manual must be followed exactly.
Top of Heater
Back of Heater
Front of Heater
Sides of Heater
Floor
Vent/Air Intake
6 inches
0 inch
6 inches
2 inches
12 inches
0 inches
26