Robertshaw RS4110 Installation Manual page 10

Rs4000 series rs5000 series rs6000 series
Hide thumbs Also See for RS4110:
Table of Contents

Advertisement

Available languages

Available languages

Pop-Up Wizard
The Wizard routine will display factory default settings. Each setting will
display for ten seconds. Use the
setting. Settings that are not changed will operate with the values that
are displayed. To fast forward through the Wizard, press Edit Schedule.
The Wizard can be exited by pressing Start/Stop Schedule. This will
save the settings and place the thermostat into operation.
Use this chart to write down the desired settings before applying power.
Settings may vary by model.
Displayed
Details
SCAL
choose °F or °C
CLOC
choose 12 or 24 hour
LITE
y = always on, n = off
DIFF
differential, set between 0.5 to 3.0 °F
or 0.5 to 1.5 °C
DIF2
2nd stage differential,
added to first stage differential
DLY2
2nd stage delay, in minutes
DLY3
3rd stage delay, in minutes
AUTO
auto changeover enable
DEDB
auto changeover deadband
in degrees
HI
heat setting limit in degrees
LO
cool setting limit in degrees
VAC HEAT
vacation heat setpoint in degrees
VAC COOL
vacation cool setpoint in degrees
CHECK
check filter timer in hours
CYCL
compressor short cycle delay in minutes
CAL
calibration offset in degrees
After the Wizard has configured the thermostat, the settings can be
edited by pressing
change settings.
Factory settings that have not been changed will use the default settings
for operation.
or
and
simultaneously. This will allow you to
10
buttons to change the
Default Change To
°F
12
y
1 °F
2 °F
20
20
y
3 °F
90 °F
45 °F
62 °F
85 °F
n or OFF
5
0
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______