58
Maintenance / Service
Messages to signal necessary maintenance work. The following
causes may be the reason for the occurance of a maintenance mes-
sage:
– Burner operating hours interval time exceeded since the last
maintenance work
– Start-up interval time exceeded since the last maintenance
– Number of month exceeded since the last maintenance
– Ionisation current maintenance threshold undercut
After the appearance of a maintenance message, the heating spe-
cialist has to be informed. If necessary, the heating specialist can
instruct the end user to call up the maintenance code, so that the
maintenance cause can be found. In this way, preparations can be
made to carry out servicing, if necessary.
The end user has the opportunity to acknowledge on end user level
the displayed maintenance message by editing parameters. After
this, the message is cancelled in the whole system.
Reset messages 1
1 = Individual reset of operation hours maintenance message
Reset messages 2
1 = Individual reset of start-up maintenance message
Reset messages 3
1 = Individual reset of the months-service-maintenance message
Reset messages 4
1 = Individual reset of ionisation current maintenance message
Reset messages 6
1 = Total reset of all maintenance messages
Activation of manual control. If the manual control function is ac-
tivated the boiler will be controlled to the Setpoint manual cont-
rol. All pumps will be activated. Additional request will be ignored!
State
With this function the state of the selected system can be reques-
ted.
The following messages are possible under Heating circuit 1/2:
Display
---
Manual control active
Floor curing function active
Opt start ctrl+boost heating
Optimum start control
Boost heating
Comfort heating mode
Optimum stop control
Reduced heating mode
Frost prot room active
Summer operation
24-hour Eco active
Setback reduced
Setback frost protection
Room temp limitation
The following messages are possible under DHW:
Display
---
Manual control active
Dependend on
No heating circuit available
Manual control active
Floor curing function active
Time switching program, operating mode, occupancy button
Time switching program, holiday program, operating mode, occu-
pancy button, H1
Holiday program, operating mode, H1
Time switching program, holiday program, operating mode, occu-
pancy button, H1
Holiday program, operating mode, H1
Dependend on
Not available
Manual control active