Kenwood TS-990S Service Manual page 58

Hf/50mhz transceiver & external speaker
Hide thumbs Also See for TS-990S:
Table of Contents

Advertisement

TS-990S
Ref. No.
Use/Function
Q951,952
Switching
Q953,954
Switching
Q955,956
Switching
Q957,958
Switching
Q959,960
Switching
Q961,962
Switching
Q963,964
Switching
Q965,966
Switching
Q967
Switching
Q968
Switching
Q969
Switching
Q970
Switching
Q971,972
Switching
Q973,974
Switching
Q975
Switching
D103,104
Clipper
D105
Surge protection
D106
Mute
D107
Mute
D110~ 112 Surge protection
Reverse current
D113
prevention
D114
Surge protection
Reverse current
D115
prevention
D116
Surge absorption
D117
Surge protection
58
COMPONENTS DESCRIPTION
Operation/Condition/Compatibility
Power supply control of sub RX
circuit (ON during sub reception)
Power supply control of sub RX
preamplifi er (ON when sub RX
preamplifi er is ON)
Power supply control of sub RX
preamplifi er (ON when sub RX
preamplifi er is OFF)
Power supply control of sub RX
1st IF circuit (ON when sub RX
1st IF of 73.095MHz is selected)
Power supply control of sub RX
1st IF circuit (ON when sub RX
1st IF of 11.374MHz is selected)
Power supply control of TXB
(ON during transmission)
Power supply control of FM circuit
(ON when TX FM mode is se-
lected)
Power supply control of SRXB
(ON during sub reception)
Power supply control of sub RX
1st IF circuit (ON when sub RX
1st IF of 73.095MHz is selected)
Power supply control of sub RX
1st IF circuit (ON when sub RX
1st IF of 11.374MHz is selected)
Power supply control of sub RX
1st IF circuit (ON when sub RX
1st IF of 73.095MHz is selected)
Power supply control of sub RX
1st IF circuit (ON when sub RX
1st IF of 11.374MHz is selected)
Power supply control of 3rd IF cir-
cuit (ON when sub RX SSB, AM
and CW mode are selected)
Power supply control of FM circuit
(ON when RX FM mode is select-
ed)
Power supply control of SRXB
(ON during transmission)
External packet data input
ACC2 connector (7-pin SSQ)
For main ANO mute
For sub ANO mute
ACC2 connector (2/5/9-pin)
Invert PKS control signal
METER connector (3-pin SS-
MET)
Linear amplifi er control signal
Relay (K101)
METER connector (2-pin MS-
MET)
Ref. No.
Use/Function
Reverse current
D118
prevention
Reverse current
D119
prevention
D120,121
Surge protection
Reverse current
D171,172
prevention
D200
Surge protection
D201
Surge absorption
D202
Surge absorption
D204,205
Surge absorption
D207
Switching
D208
Switching
Reverse current
D209
prevention
D210
Switching
D211,212
Switching
D213,214
Switching
D215,216
Switching
D217,218
Switching
D219,220
Switching
D221,222
Switching
D223,224
Switching
D225,226
Switching
D227,228
Switching
D229,230
Switching
D231,232
Switching
D233,234
Switching
D235,236
Switching
D237,238
Switching
D239,240
Switching
D251,252
Surge absorption
Operation/Condition/Compatibility
KEY connector (2-pin KEY down/
Electric keyer dot signal)
KEY connector (3-pin KEY down/
Electric keyer dash signal)
ACC2 connector (6/10-pin)
Linear amplifi er control signal
Sub reciever RF signal input
Relay (K201)
Relay (K202)
Internal circuit protection
Sub RX/TX changeover, on dur-
ing sub reception
ON when sub receiveing over
1.705MHz is selected
1/2: Sub receiving ON at
30~522kHz
2/2: Sub receiving ON at
522kHz~1.705MHz
ON when sub receiveing over
1.705MHz is selected
ON when BPF of
522kHz~1.705MHz is selected
ON when BPF of 30~522kHz is
selected
ON when BPF of 1.705~2.5MHz
is selected
ON when BPF of 2.5~4.1MHz is
selected
ON when BPF of 4.1~6.9MHz is
selected
ON when BPF of 6.9~7.5MHz is
selected
ON when BPF of 7.5~10.5MHz is
selected
ON when BPF of 10.5~13.9MHz
is selected
ON when BPF of 13.9~14.5MHz
is selected
ON when BPF of 14.5~21.5MHz
is selected
ON when BPF of 21.5~30MHz is
selected
ON when BPF of 30~60MHz is
selected
ON when BPF of 49~54MHz is
selected (TX only)
ON when sub receiving preampli-
fi er is OFF
ON when sub receiving preampli-
fi er is ON
Internal circuit protection

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-990

Table of Contents