Kenwood TS-990S Service Manual page 170

Hf/50mhz transceiver & external speaker
Hide thumbs Also See for TS-990S:
Table of Contents

Advertisement

TS-990S
Item
Condition
HF BPF*1
7) Main display f.: 1.800000MHz
Mode: USB
• 1.8M
P.AMP: ON
check
Spectrum analyzer setting
Start frequency: 0MHz
Stop frequency: 6MHz
TG level: 0dBm
• 3.5M
8) Main display f.: 3.500000MHz
Mode: USB
P.AMP: ON
Spectrum analyzer setting
Start frequency: 0MHz
Stop frequency: 8MHz
TG level: 0dBm
• 5M
9) Main display f.: 5.330000MHz
Mode: USB
P.AMP: ON
Spectrum analyzer setting
Start frequency: 0MHz
Stop frequency: 10MHz
TG level: 0dBm
• 10M
10) Main display f.:
10.100000MHz
Mode: USB
P.AMP: ON
Spectrum analyzer setting
Start frequency: 2MHz
Stop frequency: 16MHz
TG level: 0dBm
• 18M
11) Main display f.:
18.100000MHz
Mode: USB
P.AMP: ON
Spectrum analyzer setting
Start frequency: 8MHz
Stop frequency: 26MHz
TG level: 0dBm
• 24M
12) Main display f.:
24.900000MHz
Mode: USB
P.AMP: ON
Spectrum analyzer setting
Start frequency: 0MHz
Stop frequency: 50MHz
TG level: -10dBm
170
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Tracking
RX
CN1
generator
(A/2)
CN93
Spectrum
analyzer
Adjustment
Parts
Method
Check that it is the
frequency response
1.705MHz 2.50MHz
as shown.
Specifi cations/Remarks
2.50MHz 4.10MHz
4.10MHz 6.00MHz
7.50MHz 10.50MHz
14.50MHz
18.50MHz
21.50MHz 26.50MHz

Hide quick links: