Kenwood TS-990S Service Manual page 180

Hf/50mhz transceiver & external speaker
Hide thumbs Also See for TS-990S:
Table of Contents

Advertisement

TS-990S
Item
Condition
18. SUB RX HF
1) Sub display f.: 135kHz
BPF
Mode: USB
P.AMP: OFF
• 30k~522k
Spectrum analyzer setting
Start frequency: 0MHz
Stop frequency: 1.2MHz
TG level: 0dBm
• 522k~
2) Sub display f.: 525kHz
~1.705M
Mode: USB
P.AMP: OFF
Spectrum analyzer setting
Start frequency: 0MHz
Stop frequency: 2.5MHz
TG level: 0dBm
• 1.8M
3) Sub display f.: 1.800000MHz
Mode: USB
P.AMP: OFF
Spectrum analyzer setting
Start frequency: 0MHz
Stop frequency: 4MHz
TG level: 0dBm
• 3.5M
4) Sub display f.: 3.500000MHz
Mode: USB
P.AMP: OFF
Spectrum analyzer setting
Start frequency: 0MHz
Stop frequency: 6MHz
TG level: 0dBm
• 5M
5) Sub display f.: 5.300000MHz
Mode: USB
P.AMP: OFF
Spectrum analyzer setting
Start frequency: 0MHz
Stop frequency: 12MHz
TG level: 0dBm
• 10M
6) Sub display f.: 10.100000MHz
Mode: USB
P.AMP: OFF
Spectrum analyzer setting
Start frequency: 2MHz
Stop frequency: 16MHz
TG level: 0dBm
180
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Tracking
TX-RX
CN200
generator
(A/2)
CN230
Spectrum
analyzer
Adjustment
Parts
Method
Check the waveform.
Specifi cations/Remarks
30kHz
522kHz
522kHz
1.705MHz
1.705MHz 2.50MHz
2.50MHz
4.10MHz
4.10MHz
6.90MHz
7.50MHz
10.50MHz