Item
Condition
31. HF PGC
1) Menu No.: 97 (14.1MHz, CW)
Transmit
• 100W
• 50W
2) Menu No.: 98 (14.1MHz, CW)
Transmit
• 25W
3) Menu No.: 99 (14.1MHz, CW)
Transmit
• 10W
4) Menu No.: 100 (14.1MHz,
CW)
Transmit
• 5W
5) Menu No.: 101 (14.1MHz,
CW)
Transmit
32. FM
1) Menu No.: 102 (29.1MHz,
deviation
FM)
Transmit
• Wide
• Narrow
2) Menu No.: 103 (29.1MHz,
FM)
Transmit
33. SCOPE
1) Menu No.: 113 (14.1MHz,
gain
CW)
Transmit
34. Protection
1) Menu No.: 105 (14.1MHz,
CW)
• 14M
Transmit
Use a cable that is 1m long
TS-990
(1m cable)
Power meter
(Direct connection)
150 dummy load
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power
Rear
ANT1
Front
meter
panel
panel
500W ATT
Power
Rear
ANT1
Front
meter
panel
panel
Linear
detector
500W ATT
Power
Rear
ANT1
Front
meter
panel
panel
500W ATT
150
Rear
ANT1
Front
dummy
panel
panel
load
Through
type
power
meter
TS-990S
Adjustment
Parts
Method
[UP]/
Adjust the ALC
ALC meter 35 dots
[+](F5)
meter zone to maxi-
or
mum.
[DOWN]
/[-](F4)
[UP]/
4.2kHz
±0.05kHz
[+](F5)
According to the
or
larger +, –.
[DOWN]
/[-](F4)
2.1kHz
±0.05kHz
According to the
larger +, –.
[[UP]/
1 push
[UP-
DATE]
(F5)
[UP]/
Set the adjustment
80W±2W
[+](F5)
value wiithin the
or
limit of the specifi ed
[DOWN]
power.
/[-](F4)
Specifi cations/Remarks
203