Kenwood TS-990S Service Manual page 178

Hf/50mhz transceiver & external speaker
Hide thumbs Also See for TS-990S:
Table of Contents

Advertisement

TS-990S
Item
Condition
12. Carrier point
1) Menu No.: 6 (1.81MHz, USB)
P.AMP: OFF
• XF8/2.7kHz
AGC: OFF
FIL/SEL(M): 2.7kHz
SSG1 f.: 1.813MHz
SSG2 f.: 1.810MHz
SSG output: –33dBm
(5.01mV)
• XF5/500Hz 2) Menu No.: 7 (1.81MHz, CW)
P.AMP: OFF
AGC: OFF
FIL/SEL(M): 500Hz
SSG1 f.: 1.810275MHz
SSG2 f.: 1.809725MHz
SSG output: –33dBm
(5.01mV)
• XF6/270Hz 3) Menu No.: 8 (1.81MHz, CW)
P.AMP: OFF
AGC: OFF
FIL/SEL(M): 270Hz
SSG1 f.: 1.810145MHz
SSG2 f.: 1.809855MHz
SSG output: –33dBm
(5.01mV)
13. SUB RX
1) Menu No.: 45 (100kHz, USB)
1st mixer bal-
P.AMP: OFF
ance
ANT: Open (X57-827 A/2
CN200 Open)
14. SUB RX
1) Sub display f.: 1.800000MHz
Trap fre-
Mode: USB
quency
P.AMP: ON
Spectrum analyzer setting
• 1MHz
Start frequency: 0MHz
Stop frequency: 3MHz
TG level: -10dBm
Disconnect the cable from
CN200 and connect the
tracking generator output to
CN200.
Connect the spectrum ana-
lyzer input to CN230.
178
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG1
RX
CN1
Front
SSG2
(A/2)
TP1
panel
2 signal
pad
Oscillo-
scope
AF VM
Rear
EXT.
TX-RX
panel
SP2
(A/2)
Tracking
TX-RX
CN200
TX-RX
generator
(A/2)
CN230
(A/2)
Spectrum
analyzer
Adjustment
Parts
Method
[UP]/[+]
Change the adjust-
(F5) or
ment values to get
[DOWN]
the waveform as
/[-](F4)
shown.
VR401 Noise min.
Note: When the noise level
minimum is not understood,
adjust the volume position of
VR401 as shown in the fi gure
below.
L208
Adjust the coil to get
a null point at 1MHz
as shown.
Specifi cations/Remarks
OK
NG
1.00MHz
1.705MHz

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-990

Table of Contents