Kenwood TS-990S Service Manual page 187

Hf/50mhz transceiver & external speaker
Hide thumbs Also See for TS-990S:
Table of Contents

Advertisement

Item
Condition
MAIN RX
2) Menu No.: 31 (50.2MHz, FM)
50M FM S-
FIL/SEL(M): 15kHz
meter
SSG f.: 50.200MHz
SSG output: –95dBm
• Full scale
(3.98µV)
(Lights up
MOD: 1kHz
all)
DEV: 3kHz
• Full scale
3) Menu No.: 32 (50.2MHz, FM)
2 (Lights up
FIL/SEL(M): 15kHz
all)
SSG f.: 50.200MHz
SSG output: -81dBm
(19.9µV)
MOD: 1kHz
DEV: 3kHz
41. MAIN RX
1) Menu No.: 33 (50.2MHz, FM)
50M FM SQL
FIL/SEL(M): 15kHz
threshold
SSG f.: 50.200MHz
SSG output: OFF
MOD: 1kHz
DEV: 3kHz
42. MAIN RX
1) Menu No.: 34 (50.2MHz, FM)
50M FM SQL
FIL/SEL(M): 15kHz
tight
SSG f.: 50.200MHz
SSG output: –113dBm
(0.501µV)
MOD: 1kHz
DEV: 3kHz
43. SCOPE
1) Menu No.: 35 (14.2MHz, CW)
gain
P.AMP: ON
FIL/SEL(M): 2.7kHz
SSG f.: 14.2MHz
SSG output: –40dBm
(2.24mV)
44. SUB
1) Menu No.: 40 (14.2MHz,
RX AGC
USB)
start level
P.AMP: ON
(73M/6kHz)
FIL/SEL(S): 10M 6kHz
AGC: OFF
SSG f.: 14.201MHz
SSG output: –110dBm
(0.707µV)
45. SUB RX
1) Menu No.: 41 (14.2MHz,
AGC start
USB)
level
P.AMP: ON
(73M/
FIL/SEL(S): 10M 2.7kHz
2.7kHz)
AGC: OFF
SSG f.: 14.201MHz
SSG output: –110dBm
(0.707µV)
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
Rear
ANT 1
Front
panel
panel
TS-990S
Adjustment
Parts
Method
[UP]/
Set the SSG, press
[UP-
the [UP]/[UPDATE]
DATE]
(F5) key.
(F5)
[UP]/[+]
Using the [UP]/[+]
(F5) or
(F5) or [DOWN]/[-]
[DOWN]
(F4) key, adjust to
/[-](F4)
the point when "A/D
data" displays "1" for
the fi rst time.
Specifi cations/Remarks
187

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-990

Table of Contents