Group:motor Rating Parameters; Programmable Pointer Registers - Toshiba TOSVERT-130 G3 Interface Manual

High performance transistor inverter true torque control drive series
Hide thumbs Also See for TOSVERT-130 G3:
Table of Contents

Advertisement

efesotomasyon.com -Toshiba inverter,drive,servo,plc

9.3.13 GROUP:MOTOR RATING PARAMETERS

Register
Function / Title
242
NUMBER OF MOTOR
POLES
243
MOTOR RATED
CAPACITY
244
MOTOR TYPE
245
2
MOTOR RATED
VOLTAGE
(230 / 460v units)
246
247
MOTOR RATED
FREQUENCY
248
MOTOR RATED RPM
249
AUTO-TUNING
ENABLE
24A
LOAD MOMENT OF
INERTIA

9.3.14 Programmable Pointer Registers

Register
Function / Title
24B ∼
Programmable Address
26A
Registers (32 total)
26B ∼
Programmable Data
28A
Registers (32 total)
Bank
0 / 1
0 / 1
0 / 1
0 / 1
(575v units)
0 / 1
0 / 1
0
0 / 1
Bank
0
According to the attributes of the registers programmed in 24B∼26A
Mask
Adjustment Range
00FF
0001: (2)
0002: (4)
0003: (6)
0004: (8)
0005: (10)
0006: (12)
0007: (14)
0008: (16)
0001 ∼ 270F (0.1 ∼ 999.9)
FFFF
0030
0000:Toshiba EQPIII motor
0010:Toshiba STD motor
0020:Other
0012 ∼ 0078 (90 ∼ 600)
00FF
001A ∼ 00AC (130 ∼ 860)
0000 ∼ 00C8 (0 ∼ 400)
00FF
0000 ∼ 270F (0 ∼ 9999)
FFFF
0008
0000: Auto-tuning disabled
0008: Auto-tuning enabled
00C0
0000: Small
0040: Medium
0080: Large
00C0: Very large
Mask
Adjustment Range
1 ∼ 24A
FFFF
47
Multiplier
2
0.1
(0)
(1)
(2)
5
2
1
(0)
(1)
(0)
(1)
(2)
(3)
Multiplier

Advertisement

Table of Contents
loading