Group:pattern Run Control Parameters - Toshiba TOSVERT-130 G3 Interface Manual

High performance transistor inverter true torque control drive series
Hide thumbs Also See for TOSVERT-130 G3:
Table of Contents

Advertisement

efesotomasyon.com -Toshiba inverter,drive,servo,plc

9.3.8 GROUP:PATTERN RUN CONTROL PARAMETERS

Register
Function / Title
146
PATTERN RUN
SELECTION
147
1
PATTERN RUN
CONTINUE MODE
148
PATTERN GROUP #1
SPEED #0
149
PATTERN GROUP #1
SPEED #1
150
PATTERN GROUP #1
SPEED #2
151
PATTERN GROUP #1
SPEED #3
152
PATTERN GROUP #1
SPEED #4
153
PATTERN GROUP #1
SPEED #5
154
PATTERN GROUP #1
SPEED #6
155
PATTERN GROUP #1
SPEED #7
156
PATTERN GROUP #1
NUMBER OF CYCLES
157
PATTERN GROUP #2
SPEED #0
158
PATTERN GROUP #2
SPEED #1
159
PATTERN GROUP #2
SPEED #2
15A
PATTERN GROUP #2
SPEED #3
15B
PATTERN GROUP #2
SPEED #4
15C
PATTERN GROUP #2
SPEED #5
15D
PATTERN GROUP #2
SPEED #6
15E
PATTERN GROUP #2
SPEED #7
15F
PATTERN GROUP #2
NUMBER OF CYCLES
160
PATTERN GROUP #3
SPEED #0
161
PATTERN GROUP #3
SPEED #1
162
PATTERN GROUP #3
SPEED #2
163
PATTERN GROUP #3
SPEED #3
164
PATTERN GROUP #3
SPEED #4
165
PATTERN GROUP #3
SPEED #5
166
PATTERN GROUP #3
SPEED #6
167
PATTERN GROUP #3
SPEED #7
168
PATTERN GROUP #3
NUMBER OF CYCLES
Bank
Mask
0 / 1
0008
0000: OFF
0008: ON
0 / 1
0001
0000: reset on stop
0001: switch when done
1
00FF
0000: Skip
0001 ∼ 000F: Speeds 1 ∼ 15
0001 ∼ 00FF: 1 ∼ 255
0 / 1
00FF
1
00FF
0000: Skip
0001 ∼ 000F: Speeds 1 ∼ 15
0001 ∼ 00FF: 1 ∼ 255
0 / 1
00FF
1
00FF
0000: Skip
0001 ∼ 000F: Speeds 1 ∼ 15
0001 ∼ 00FF: 1 ∼ 255
0 / 1
00FF
39
Adjustment Range
(0)
(1)
(0)
(1)
(0)
(0)
(0)
Multiplier
1
1
1
1
1
1

Advertisement