Display
Function
aU1
Automatic acceleration and deceleration
aU2
Automatic torque boost *
* These parameters cannot be
changed while running
aU3
Automatic environment setting *
cMOd
Command mode selection
fMOd
Frequency setting mode selection
fMsl
FM terminal function selection
fM
Connected meter adjustment
typ
Standard setting mode selection *
fr
Forward/reverse selection (Panel)
acc
Acceleration time #1 (s)
dec
Deceleration time #1 (s)
fH
Max. frequency (Hz) *
UL
Upper limit frequency (Hz)
ll
Lower limit frequency (Hz)
ul
Base frequency (Hz)
pt
V/f pattern *
ub
Voltage boost (%)
OLM
Selection of electronic thermal protection
characteristics
Sr1~
Preset speed 1 to 7. (Hz)
Sr7
F---
Extended parameters
grU
Automatic edit function
TOSHIBA
Parameter List

Basic Parameters (Group No. 00)

0: No, 1: Yes
0: No
1: Automatic torque boost
2: Sensorless vector control
3: Sensorless vector control with automatic tuning
0: No
1: Automatic 50 Hz motor
2: Automatic 60 Hz motor
0: Terminal block, 1: Panel
0: Terminal block, 1: Panel , 2: Built-in potentiometer
0: Frequency meter, 1: Output current meter
Frequency or current displayed
0: No action,
1: 50 Hz standard
2: 60 Hz standard
3: Default setting
4: Clears error log
5: Clearing accumulated operation time
6: Initialize inverter typeform
0: Forward, 1: Reverse
0: Constant V/f
1: Square reduction
2: Automatic torque boost
3: Sensorless vector control
4: Automatic energy saving
0.0 ~ 30.0 Refer to Default Value table page 52
Setting
Type
0
Standard
1
motor
2
3
4
V/F
5
motor
6
7
Changed parameters displayed
36
Adjustable range
0.1 ~ 3600
0.1 ~ 3600
30.0 ~ 320.0
0.5 ~ FH
0.0 ~ UL
25.0 ~ 320.0
Overload
Overload
protection
stall
O
O
X
X
O
O
X
X
LL ~ UL
---
Default
value
0
0
0
1
2
0
-
3
0
10.0
10.0
80.0
80.0
0.0
60.0
0
Table
0
X
O
X
O
X
O
X
O
0.0