50. [TC GEN MODE] switch
Selects the generator mode for timecode recording.
The external timecode value is recorded as
EXT RUN
the start time.
Runs the internal generator by the free run
FREE RUN
mode, and records the current internal gen-
erator time as the start time.
When recording timecode to a new file, the
generator records timecode from the value
REC RUN
which continues to the last timecode value of
the previous file.
Timecode starts from the current time of the
24H RUN
internal clock of the unit.
51. [CLOCK] switch
Selects the system master clock.
The internal clock is the master. "-INT-" is lit
INT
on the display.
The external word clock is the master. "-
WORD
WORD-" flashes on the display, which lights
steadily when the unit locks to the word clock.
The external video clock is the master. "-
VIDEO
VIDEO-" flashes on the display, which lights
steadily when the unit locks to the video clock.
The external clock available in the digital sig-
nal received via the [DIGITAL INPUT] con-
DIGITAL
nector is the master. "-DIGITAL-" flashes on
the display, which lights steadily when the unit
locks to the clock.
52. Analog Input Siginal controls
Adjust the input levels for tracks 1, 2, 3, and 4 when
recording analog signals.
The outer knob controls track 1 and 3, while the
inner knob controls track 2 and 4.
53. [BYPASS ON/OFF] switch
Select whether bypassing the [INPUT LEVEL] con-
trols or not when recording analog signals.
When set to OFF, the corresponding [INPUT LEVEL]
controls are active.
When set to ON, the corresponding [INPUT LEVEL]
controls are inactive.