Test Run - Mitsubishi Electric FR-D700 Instruction Manual

Hide thumbs Also See for FR-D700:
Table of Contents

Advertisement

(2)
Selection method of general-purpose magnetic flux vector control
Display the extended function parameters.
Mitsubishi standard
SF-JR
motor
SF-HR
Mitsubishi high
Others
efficiency motor
SF-JRCA 4P
Mitsubishi constant-
SF-HRCA
torque motor
Others (SF-JRC, etc.)
Other standard motor
Other constant-
torque motor
∗1
Refer to page 98, for other settings of Pr. 71.
∗2
Refer to page 100 for offline auto tuning.
Set the operation command. (Refer to page 160)
As required
Perform offline auto tuning. (Pr. 96) (Refer to page 100)
Set slip compensation. (Pr. 245, Pr. 246, Pr. 247) (Refer to page 73)
NOTE
Uneven rotation slightly increases as compared to the V/F control. (It is not suitable for machines such as grinding
machine and wrapping machine which requires less uneven rotation at low speed.
When a surge voltage suppression filter (FR-ASF-H/FR-BMF-H) is connected between the inverter and motor, output
torque may decrease.)
Adjust the output torque (current) of the motor
Perform secure wiring.
(Refer to page 14)
(Pr. 160) (Refer to page 157)
Set "0" in Pr. 160 to display the extended function parameters.
Set the motor. (Pr. 71)
Motor
Set the motor capacity.
(Pr. 80) (Refer to page 74)
Set motor capacity (kW) in Pr. 80 Motor capacity.
(V/F control is performed when the setting is "9999" (initial value).
Select the start command and speed command.
(1)Start command
1)Operation panel: Setting by pressing
2)External command: Setting by forward rotation or reverse rotation
command (terminal STF or STR)
(2)Speed command
1)Operation panel: Setting by pressing
2)External analog command (terminal 2 or 4):
Give a speed command using the analog signal input to terminal 2 (or
terminal 4).
3)Multi-speed command:
The external signals (RH, RM, RL) may also be used to give speed
command.

Test run

Pr. 71 Setting ∗1
0 (initial value)
40
3
Offline auto tuning is necessary.
1
50
13
Offline auto tuning is necessary.
3
Offline auto tuning is necessary.
13
Offline auto tuning is necessary.
Remarks
∗2
∗2
∗2
∗2
of the operation panel
of the operation panel
71
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents