Dark Background Density (Figure 5-3 B ); Blank Paper Is Output (Figure 5-3 C ) - Oki B4500 Maintenance Manual

Monochrome led page printer
Hide thumbs Also See for B4500:
Table of Contents

Advertisement

2
Dark background density
• Has the image drum been exposed to external light?
• Yes
Install the image drum in the printer and wait about 30 minutes.
• No
Perform the cleaning page function (see Section 4.2.2).
• Has the problem been solved?
• Yes
End
• No
Is the heat roller of the fusing unit dirty?
• Yes
Clean the heat roller.
• No
Is the contact of the cleaning roller of the image drum cartridge in contact with the contact
assembly properly (see Figure 5-4
• No
Adjust the contact of the cleaning roller to make a proper contact with the contact
assembly.
• Yes
Replace the image drum cartridge.
• Has the problem been solved?
• Yes
End
Note: After replacing the image drum cartridge, reset the drum counter (see User's
• No
Replace the main control board or high voltage/sensor board.
3
Blank paper is output.
• Is the LED head being connected properly (check the HEAD connector on the main control board and
PC connector on the LED head)?
• No
Connect the LED head properly or replace the head cable.
• Yes
Is the contact of the image drum cartrige in proper contact with the ground contact properly (see
Figure 5-4
• No
Adjust the ground contact (Drum) of the contact assembly.
• Yes
Replace the LED head.
• Has the problem been solved?
• Yes
End
• No
Replace the main control board or high voltage/sensor board.