2.3.8
Face Up Stacker Assy
(1) Remove the upper cover assy (see 2.3.1).
(2) Remove the operator panel assy (see 2.3.3).
(3) Remove four screws 1 and remove both the shield plate 2 and face up stacker 3 together.
(4) Unlock the latches at two locations, and remove the face up stacker 3.
Note :
Be careful not to touch (or rotate) the DC motor thoughtlessly. Rotating the DM motor
counterclockwise removes the eject spring. (Refer to 2.3.9.)
1
43502101TH Rev.1
3
1
2
Oki Data CONFIDENTIAL
1
27 /