(12) Fixing the temporary stop switch
The temporary stop switch has been in the state as shown in figure A at the time of delivery.
Loosen setscrew q and set the switch in the state as shown in figure B, and fix it with setscrew q together
with setscrew w supplied with the machine.
q
(13) Thread guide rod
Thread guide rod
(14) Installing the thread stand
w
q
\
A
11
q
Securely fit the thread guide rod so that two side holes
in the thread guide rod face the thread guide.
1) Assemble the thread stand, and set it in the hole
in the top right corner of the machine table.
2) Tighten locknut q to fix the thread stand.
3) When ceiling wiring is possible, pass the power
cable through spool rest rod w.
w
B