Jackson Avenger HT Installation/Operation & Technical Manual page 24

Undercounter dishmachine series
Table of Contents

Advertisement

WARNING: Inspection, testing and repair of electrical equipment should be performed only by qualified service per-
sonnel. Certain procedures in this section require electrical tests or measurements while power is applied to the
machine. Exercise extreme caution at all times. If test points are not easily accessible, disconnect power, attach test
equipment and reapply power to test. When replacing electrical parts, disconnect power at source circuit breaker.
Problem: Rinse water not at required temperature range.
1. Check that orange/white wires are connected. See note in installation instructions.
2. Thermometer is defective. Replace.
3. Thermostat is defective. Adjust the thermostat. Replace if necessary.
4. Incoming rinse water does not meet minimum criteria indicated on machine data plate. Adjust as required.
Problem: Machine doesn't drain when "OFF/DRAIN" switch is pressed.
1. Drain solenoid clogged. Remove obstruction.
2. Defective motor or motor start relay. Replace.
3. Defective drain valve. Replace.
Problem: No indication of pressure.
1. Water turned off. Turn water on.
2. Pressure gauge defective. Replace pressure gauge.
SECTION 4: TROUBLESHOOTING SECTION
COMMON PROBLEMS
Avenger™ Series Technical Manual 7610-003-34-01
Issued: 10-07-2007 Revised: N/A
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avenger ltAvenger htavenger lth

Table of Contents