Power/Connections
Approximate Total Load
208V / 60HZ / 3PH
208V / 60HZ / 1PH
230V / 60HZ / 3PH
230V / 60HZ / 1PH
460V / 60HZ / 3PH
Booster Heater Options
External 40°F Min. Rise
208V / 60HZ / 3PH
230V / 60HZ / 3PH
460V / 60HZ / 3PH
External 70°F Min. Rise
208V / 60HZ / 3PH
230V / 60HZ / 3PH
460V / 60HZ / 3PH
Venting Requirements (CFM)
Input end
Output end
Total CFM
Water Requirements
Incoming Wash Tank Temperature (°F)
With 36 KW booster heater option (°F)
With 45 KW booster heater option (°F)
Gallons per hour
Gallons per rack
Wash Tank Capacity (Gallons)
Incoming Waterline Size (IPS) (Minimum)
Flow Pressure (PSI)
Flow Rate Minimum (GPM)
Drainline Size IPS (Minimum) (Inches)
Standard Features
• 287 racks per hour hi-temp sanitizing
rinse
• 0.77 gallons per rack hi-temp sanitizing
rinse
• Incoming water pressure regulator
• Exclusive Adjust-A-Peak feature
(patented) allows the owner operator
to manually adjust the speed of the
conveyor system from 144 racks per
hour all the way to maximum capacity
of 287 racks per hour.
• Standard 25" clearance allows
owner operators the ability to wash
large utensils, trays, and bun pans.
• Totally electro-mechanical; no solid
state controls utilized.
• Fully automatic including auto-fill.
AMPS
81.8
138.9
75.1
127.5
37.6
KW
AMPS
34.5
95.8
Performance/Capacities
36
90.5
36
45.2
Operating Capacity
KW
AMPS
Racks per hour
45
125.0
Dishes per hour
45
108.0
Glasses per hour
45
54.0
Steam Coil Tank Heat
Steam Connection IPS (Inches)
200
Steam Flow Pressure (PSIG)
400
Consumption @ 15 PSIG (Lbs/hr) 100
600
Wash Pump Motor HP
Wash Pump Capacity (GPM)
180
Wash Tank KW
140
Conveyor Motor Horsepower
110
Conveyor Speed (Feet/minute)
222
0.77
15.4
3/4
15-25
3.7
1 1/2
AJ-64 Vision Series
287
7200
7200
3/4
10-20
2
270
15
1/4
8.0
• Completely self-draining, stainless
steel wash and recirculating rinse
pumps.
• Exclusive "Energy Guard" controls
system energizes wash, recirculating
rinse, and final rinse sections only
when a rack is in place.
• Convenient, externally operated
lever drains.
• Stainless steel frame, legs, adjustable
bullet feet, and front appearance
panel are all standard.
• Standard 8" vent cowls/splash
shields on both wash and rinse ends
of the machine.
• Heavy gauge construction for extra
ruggedness and durability.
Operating Temperatures
Wash Tank–°F (Minimum)
Power Rinse–°F (Minimum)
Rinse–°F (Minimum)
Dimensions (Inches)
Length between dishtables
Machine width
Wall Clearance (Minimum)
Cavity/dish clearance (Maximum)
Shipping Information
Weight (Lbs)
Dimensions (Inches)
Length
Depth
Height
Volume (Cubic feet)
174.0
150
160
180
64
25
4.5
25
890
96
40
78

Advertisement

loading

Summary of Contents for Jackson Vision Series AJ-64

  • Page 1 Power/Connections Approximate Total Load 208V / 60HZ / 3PH 208V / 60HZ / 1PH 230V / 60HZ / 3PH 230V / 60HZ / 1PH 460V / 60HZ / 3PH Booster Heater Options External 40°F Min. Rise 208V / 60HZ / 3PH 34.5 230V / 60HZ / 3PH 460V / 60HZ / 3PH...
  • Page 2: Specifications

    Standards Association (CSA). They also meet the require- ments of A.S.S.E. Standard No. 1004. PERFORMANCE: Fully automatic, multiple tank, rack conveyor dishwasher designed to wash, rinse, and sanitize tableware and utensils commonly associated with the preparation and consumption of food items in a commercial foodservice operation.
  • Page 3: Pressure Reducing Valve

    Power to the booster heater requires a separate electrical connection. Unless speci- fied otherwise, electrical characteristics of the booster heater will be the same as that of the dishwasher. The booster heater is available in 208/240/480 voltages/3 phase only.
  • Page 4 Specifications Note: Check and/or copy all that apply. AJ-64 Series Rack Conveyor Dishwasher—Item No. ____________ Shall be a Jackson AJ-64 Series, multiple tank rack conveyor dishwasher. Sanitization shall be accomplished by using hi-temp (180°F minimum) sanitizing rinse. Electrical characteristics shall be:...
  • Page 5 Left to Right or Right to Left Operation Shown Legend to Drawing A– Electrical Connection - See Table for Amperage Requirements (on back) B– Water Inlet-3/4” I.P.S., 180°F Water Required C– Drain Connection-1 1/2” I.P.S. D– Vent Collar/Splash Shield E– Vent Collar with Damper 4”w. x 16”lg x 7”high-Optional F–...
  • Page 6 AJ-64 Approximate Total Load Amperes Power Supply AJ-64CE 208/60/1 138.9 230/60/1 127.5 208/60/3 81.8 230/60/3 75.1 460/60/3 37.6 Recommended Table Fabrication Rack Rail Rack Rail Height Above Dishtable 1/4" – 5/16" 10 1/2" 21" Opening w w w. j a ck s o n m s c . c o m 1 - 8 8 8 - 8 0 0 - 5 67 2 Conveyors AJ-64CS...

This manual is also suitable for: