Figure 35. Attach Blower to
the stove bottom and
connect wires to Snapstat
and female control quick
connect.

Blower Operation

The optional variable-speed blower will enhance heat
circulation around the firebox and out into the room.
The blower is controlled by a heat activated switch
(snapstat) that will ONLY function when the control
switch is in AUTO setting. After the fire has been
burning for a time, the snapstat will react to the heat
and activate the blower. Fan speed may be manually
adjusted with the rheostat knob. If the burner turns off,
the blower will be shut off automatically when the
stove cools down.
If automatic blower circulation is not desired, place
the blower control switch in the MANUAL position.
Speed
Control
Figure 36. Blower Controls
Snapstat
Connectors
M6 x 20 mm
Hex Bolts
Figure 37. Blower Wiring Diagram
Manual or
Automatic
Modes
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS
OPERATION.
VERIFY OPERATION AFTER SERVICING.
Au moment de l'entrentien des commandes,
etiquietez tous le fils avant le debranchement.
es erreurs de ceblage peuvent entra tun
fonctionnement inadequat et dangereux.
Male
Quickconnector
Female
Quickconnector
CAUTION:
ATTENTION: