Service Tools; Specifications; Dimensions - Jøtul GF 300 BV Allagash Installation And Operation Instructions Manual

Jotul gf300 bv allagash gas stove installation and operation instructions
Table of Contents

Advertisement

GF 300 BV Allagash

Specifications

The Jøtul GF300 BV Allagash is a atmospherically-
vented gas fireplace heater designed only for
vertical venting directly to the outside of the house,
using listed, Type B-vent pipe.
Input Rates
Natural Gas
26,000 BTU/hr. maximum input
15,000 BTU/hr. minimum input
Propane
26,000 BTU/hr. maximum input
13,500 BTU/hr. minimum input
Inlet Pressure:
MIN
Natural Gas:
5.0 WC (1.24 kPa)
Propane:
12.0 WC (2.99 kPa) 14.9 WC (3.71 kPa)
Manifold Pressure:
MIN
Natural Gas:
1.2 WC (.30 kPa)
Propane:
2.9 WC (.722 kPa)
Piezo Ignitor / Standing Pilot
4 1/2"
114 mm
C L
4
MAX
7.0 WC (1.74 kPa)
MAX
3.8 WC (.95 kPa)
11.0 WC (2.74 kPa)
C L
11 1/2"
292 mm
16 1/2"
420 mm
23"
584 mm
27 3/4"
705 mm
22 1/4"
565 mm
THIS FIREPLACE IS SHIPPED FROM THE FACTORY
FOR USE WITH NATURAL GAS ONLY. FOR USE WITH
PROPANE, THE APPLIANCE MUST FIRST BE
CONVERTED USING #155592 FUEL CONVERSION KIT
PROVIDED. CONVERSION SHOULD BE MADE
BEFORE THE APPLIANCE IS INSTALLED. SEE PG. 11.
Suggested Tools for
Installation and Service
• External regulator (for Propane only)
• Piping which complies with local code
• Manual shutoff valve (T-Handle in Massachusetts)
• Sediment trap - if required by code
• Tee joint
• Pipe wrench
• Pipe sealant
• 10 mm open end wrench
• 1/2", 7/16" open end wrench or deep socket
• Phillips head screwdriver
• Flat head screwdriver
• 1/4" nut driver
• 4 mm allen wrench
• Gloves
• Safety glasses
• Torx T20 screwdriver
• Leak test solution
• Reciprocating Saw
• Power Drill
With Short Legs, reduce height by 2 1/4" ( 51 mm)
13"
330 mm
C L
Top
ExitFlue
Collar
25"
635 mm
Rear Exit
Top Plate
21 5/8 "
27 3/4"
550 mm
705 mm

Hide quick links: