USA/Canada
can be easily removed then the seal is too loose. Check
several spots around the door, and repeat the procedure
on the ash pan door as well.
If gaskets need to be replaced, scrape out the old gasket
and cement and clean the area with a wire brush. Apply
a small bead of cement and push in the new gasket. After
closing and latching the doors wipe clean, any excessive
cement that has come from beneath the gasketing.
Gasket list for the Jøtul F 3
Description
Order #
Top plate gasket
100038
Ash housing gasket 128213
Ash door gasket
200024
Glass gasket
200028
Door gasket
200024
Air manifold Gasket 200028
The Jøtul F 3 is designed to burn cleanly and efficiently
when used according to the guidelines expressed in
these operating instructions. However, to maintain the
proper performance, a yearly chimney inspection and
cleaning in necessary. Failure to keep the chimney
system free of creosote and build up could result in a
serious chimney fire.
16
Size
Length
3/8" ld
6'
sheet gasket
1/4" ld
3'
1/4" ld
3'6"
11/32" ld
5'
3/16"
16"

Accessories

Many accessories have been manufactured for use with
the Jøtul F 3. Only use accessories that are specifically
designed for the Jøtul F 3.
Firescreen (part # 350168)
The Jøtul F 3 has been approved for use as an open
fireplace, with front door open. This feature is especially
nice when the ambience of a fire is desired. Some care
should be taken when operating the stove as a fireplace.
• Always have the firescreen in place, attached to the
stove front.
• Never over load the stove, for the best appearance
burn in the traditional three log configuration.
• Reminder, when burning the stove with the screen in
place, you are sacrificing efficiency for aesthetics, and
you will be consuming wood at a much faster rate.
Warning: Operate your Jøtul F 3 with the front door fully
open and the firescreen in place or fully closed. A partially
opened door may result in overfiring. Also, if the door is
left partly open, gas and flame may be drawn out of the
stove opening, creating risks from both fire and smoke.
Floor bracket kit (part #750304)
The optional floor bracket kit can be used in the event
the stove needs to be secured to the floor. Complete
installation instructions and diagrams are supplied with
each floor bracket kit.

Stove-top thermometer

(part # 5002)
Jøtul recommends the use of a magnetic stove-top
thermometer to monitor the surface temperature of the
stove. The optimum surface temperature range for the
most efficient, clean burn is between 400° and 600°.