Section Ix: Troubleshooting - New Buck Corporation 18 User Manual

Non-catalytic unit
Hide thumbs Also See for 18:
Table of Contents

Advertisement

PROBLEM
Sluggish Heater
SECTION IX
TROUBLESHOOTING
POSSIBLE CAUSE
Obstruction in chimney
Improperly sealed trim kit or
direct connect kit
Manual damper in chimney is
closed
Wet or unseasoned wood
being burned
Poor chimney draft
Improper wood loading
Page 37
SOLUTION
Check for and remove
obstruction
(a) Check trim kit gasketing
seal to fireplace and
gasket as necessary to
seal unit. Gasket under
front bottom of stove if
needed.
(b) Check seal if using direct
connect and correct.
Open manual damper and
wire shut with stainless steel
wire or remove damper
Burn dry, natural seasoned
hard wood
Improper chimney height or
wrong size flue is being used.
Cooler temperatures caused
by external chimney
Load wood length way from
front to rear

Advertisement

Table of Contents
loading

Table of Contents