New Buck Corporation 18 User Manual page 12

Non-catalytic unit
Hide thumbs Also See for 18:
Table of Contents

Advertisement

NOTE: Mount top trim panel so that it sits in front of top of side trim panels.
9. Obtain brass trim kit provided with insert kit and slip over top and sides of trim panels. Top ends of brass
may need to be trimmed to fit (See Figure 4).
10. Using insulation provided, peel and stick to back of panels overlapping fireplace dimensions by 1" on each
side and top. (See Figure 4A).
11. Next using high heat silicone or furnace cement run heavy bead of caulking around where panels meet
stove. (See Figure 4A).
12. Slide unit back into fireplace. Check to be sure that trim panels (and brass) are properly positioned
and lie flat against front of fireplace. If panels are out of position, slide unit out and reset by loosening
the mounting screws and repositioning in the slot. With bar lift stove up in front. Place insulation
across front and surface of hearth or bottom of fireplace to make complete seal.
13. To check seal of panels, use candle flame and go around entire area sealed by silicone and insulation. If flame
leans toward inside of fireplace, add additional insulation. This ensures an airtight seal.
Top Trim Panel
Side Trim Panel
FINAL CHECK
1.
Recheck specified clearances.
2. Remove all foreign material from firebox area.
3. Open primary air control
Primary Air Control: The primary air intake draft control is located at right bottom side of hearth. It
is operated by moving handle out to open (to allow air into firebox) or in (to control or close off)
air into firebox. (See Figure 4).
4. Plug power cord into a 115V AC outlet. "Do not run power cord under unit or in high traffic areas.
5. Place rumpled pieces of newspaper in stove. Light it and close door. Ensure that stove draws properly
through primary draft.
NOTE: "Do not use grate or elevate fire. Build wood fire directly on inner bottom of fire box."
6. Check for smoke leaks around door.
7. Open door and check for smoke escaping from front of stove. Smoking usually indicates a defective or poorly
positioned chimney. Some chimneys with a marginal draft can be preheated by lighting newspaper and
holding it near open damper with a poker or fire tong. Once the chimney heats up, a proper draft can usually
be obtained.
If a thorough review of Troubleshooting Guide in rear of
your dealer for assistance
Outer Trim
Buck
Stove
Primary Air Control
FIGURE 4
.
HIGH TEMP
SILICONE
FIGURE 4A
manual does not reveal problem, contact
Page 10
INSULATION

Advertisement

Table of Contents
loading