installation
To calculate the size of the heating installation, refer to the
"Available pressure" graph below.
Graph representing the available circulation pump pressure
CLAS HE EVO
5
4,5
4
3,5
3
2,5
2
1,5
1
0,5
0
0
100
200
300
400
CLAS HE EVO SYSTEM
6
5
4
3
2
1
0
0
100
200
300
400
Before the equipment is used, for the fi rst time the trap
must be fi lled with water. To do this, add approximately
1/4 litre of water via the fl ue outlet before fi tting the fl ue
system, or unscrew the cap on the trap positioned under-
neath the boiler, fi ll it with water and refi t it
Warning! Insuffi cient water in the trap can temporarily
cause the fl ue gas to be expelled into the surrounding
ambient air
16
o
ΔT20
C
38
30
24
500
600
700
800
900 1000 1100
[l\h]
500
600
700
800
900 1000

Underfl oor heating

For appliances with underfl oor heating, it is possible but not
necessary to fi t a safety thermostat onto the underfl oor heating
outlet. For the electrical connection of the thermostat see the
section on "Electrical connections - page 25".
If the outlet temperature is too high, the boiler will stop both
domestic hot water and the heating production and the error
code 1 16 "fl oor thermostat contact open" will appear on the
display. The boiler will restart when the thermostat is closed
during automatic resetting.
If the thermostat cannot be installed, the underfl oor heating
equipment must be protected by a thermostatic valve, or by a by-
pass to prevent the fl oor from reaching too high a temperature.