Ariston G.C.N.:47-116-65 (24 kW) Installation And Servicing Instructions page 45

Condensing wall-hung gas boiler
Table of Contents

Advertisement

Description
5
2
4
Compensation
5
2
5
Zone 2 heating MAXIMUM temperature
setting
5
2
6
Zone 2 heating MINIMUM temperature
setting
5
3
DIAGNOSTICS
5
3
4
Zone 2 heat request
6
ZONE 3 PARAMETER
6
0
ZONE 3 TEMPERATURE SETTING
6
0
2
Heating fi xed temperature setting
"Heating fi xed temp"
6
2
ZONE 3 SETTING
6
2
0
Heating appliance temperature value
setting
6
2
1
Basic heating control type selection type
depending on the peripheral devices
connected
6
2
2
Slope
- see graph on page 42
If the external sensor is used, the boiler calculates the most suitable heating fl ow temperature taking the external temperature
and the type of appliance into account.
The type of curve must be chosen according to the type of appliance radiator and the heat losses present in the building.
6
2
3
Parallel curve shift Zone 2 Off set
To adapt the thermal curve to the appliance requirements, it is possible to perform a parallel shift of the curve in order to alter the
calculated fl ow temperature and therefore the ambient temperature.
By accessing this parameter or pressing the buttons 12 the curve can be shifted in a parallel manner as indicated in the fi gure
shown below.
The value is indicated on the display:
- from -7 to +7 (low temperature)
- from -14 to +14 (high temperature)
Each step represents a fl ow temperature increase/decrease of 1°C in relation to the
set-point value.
6
2
4
Compensation
6
2
5
Zone 3 heating MAXIMUM temperature
setting
6
2
6
Zone 3 heating MINIMUM temperature
setting
settings - adjustment - problem identifi cation menus
value
from 0 to 20
from 35 to 85 °C
from 20 to 45 °C
from 35 to 85 °C
from 20 to 45 °C
0 = OFF
1 = ON
from 35 to 82 °C
(high temperature - para. 420 =1)
from 20 to 45 °C
(high temperature - para. 420 =0)
0 = from 20 to 45°C
(low temper ature)
1 = from 35 to 85°C
(high temperature)
0 = fi xed fl ow temperature
1 = device On/Off
2 = NOT PRESENT
3 = external sensor only
4 = NOT PRESENT
from 0_2 to 0_8
from 1_0 to 3_5
from - 7 to + 7 (low temperature)
from - 14 to + 14 (high temperature)
from 0 to 20
from 35 to 85 °C
from 20 to 45 °C
from 35 to 85 °C
from 20 to 45 °C
20
if setting = 0, the temperature
taken from the ambient sensor
does not aff ect the calculation
of the setting. If setting = 20, the
temperature taken has maximum
infl uence on the setting.
82
if parameter 520 = 1
45
if parameter 520 = 0
35
if parameter 520 = 1
25
if parameter 520 = 0
70
Activated only with temperature
control and fi xed temperature (see
621)
20
1
select in the appliance type base
1
To activate heating control, press
the AUTO button. The display
lights up the AUTO symbol
(low temperature)
1_5 (high temperature)
0
20
if setting = 0, the temperature taken
from the ambient sensor does not
aff ect the calculation of the setting.
If setting = 20, the temperature
taken has maximum infl uence on
the setting.
82
if parameter 620 = 1
45
if parameter 620 = 0
35
if parameter 620 = 1
25
if parameter 620 = 0
45