Main Heat Exchanger - Ariston G.C.N.:47-116-65 (24 kW) Installation And Servicing Instructions

Condensing wall-hung gas boiler
Table of Contents

Advertisement

MAINTENANCE GUIDE

3.17 Main heat exchanger

Tools
Drain boiler (see 3.3)
Remove the silencer
1
Remove the two clips and disconnect the pipes.
Isolate the gas supply and disconnect the gas pipe.
Remove the four screws.
2
60
Remove the burner unit
TIME
20 min
3
Remove the four screws to free the heat exchanger
4
Unscrew and lift the manual air vent from the exchanger
5

Hide quick links: