Settings - Adjustment - Problem Identifi Cation Menus; Accessing The Menus - Ariston G.C.N.:47-116-65 (24 kW) Installation And Servicing Instructions

Condensing wall-hung gas boiler
Table of Contents

Advertisement

settings - adjustment - problem identifi cation menus

Accessing the settings - adjustment - problem identifi cation
menus
The boiler can be used to manage the heating and domestic hot
water production system in its entirety.
Navigation within the menus enables the boiler system +
connected peripheral units to be customised, optimising
operation for maximum comfort and maximum saving. It also
provides important information relating to the effi cient operation
of the boiler.
Before access to the menus, the display show some "quick
settings" to have direct access to the parameters.
To see all available parameters and menu access to view FULL
MENU.
GAS - Direct access to the parameters:
220 - 231- 232- 233 - 234 - 270
SET - Direct access to the parameters:
220 - 231- 223 - 245 - 246
PCB - Direct access to the parameters:
220 - 228 - 229 - 231- 232- 233 - 234 - 247 - 250 - 253
VIS - Direct access to the parameters:
821 - 822 - 824 - 825 - 827 - 830 - 831 - 832 - 833- 840 - 835
ZONE - Direct access to the parameters:
402 - 502 - 602 - 420 - 520 - 620 -434 - 534 - 634 - 830
FULL MENU - see table on following pages
0 NETWORK
0
4
User Interface
2 Boiler Parameter
2
0
General setting
2
2
General setting
2
3
C.H. Parameters - Part 1
2
4
C.H. Parameters - Part 2
2
5
Domestic Hot Water
2
6
Boiler manual settings
2
7
Test & Utilities
2
8
Menù 2 Reset to factory setting
4 Zone 1 Parameters
4
0
Set-point Zone1
4
2
Zone 1 Setting
4
3
Diagnostics
5 Parametri Zona 2
5
0
Set-point Zone2
5
2
Zone 2 Setting
5
3
Diagnostics
6 Parametri Zona 3
6
0
Set-point Zone3
6
2
Zone 3 Setting
6
3
Diagnostics
8 Service Parameter
8
1
Statistics
8
2
Boiler
8
3
Boiler Temperature
8
4
Solar & Storage
8
5
Service
8
6
Error History
40
The parameters relating to each individual menu are listed in the
following pages.
The various parameters can be accessed and modifi ed using the OK
button and the encoder (see fi g. below).
The description of the menus and of each individual parameter will be
shown on the display.
6
7
6. E
button
SC
7. "encoder" programming knob
8. O
button programming key
K
To access the Menus, proceed as follows (for example: "231
1. Simultaneously press the
seconds
; the display show
Caution! The menus reserved for qualifi ed technicians may only
be accessed after setting the access code.
2. Turn the encoder
in a clockwise direction to select code
3. Press the OK button; the display show the fi rst "quick setting"
4. Turn the encoder
to select
5. Press the OK button; the dispaly show the menu
6. Turn the encoder
in a clockwise direction to select the menu
7. Press the OK button to access to the menu. The display show the
20
sub-menu
8. Turn the encoder
to select a sub menu
9. Press the OK button to access the sub menu parameters; the
230
display show
10. Turn the encoder
to select a parameter
11. Press the OK button to access the parameter; the display will
70
indicate the value, e.g "
Note: The parameter value will be displayed for 20 seconds, then
will begin to fl ash in alternation with the parameter, e.g. "
231
".
12. Turn the encoder
to select the new value, e.g. "
13. Press OK button to save the change or press E
saving.
To exit, press the E
button until the normal display screen is restored.
SC
For menus which do not require the access code, it is possible to pass
directly from the menu to the sub menu.
231":
ESC
OK button for 5
button and
CODE and 222
.
MENU
;
0
.
23
;
231
".
75
".
to exit without
SC
8
234
GAS
2
70
>

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents