Site Requirements
Input Power
The system requires an input power source of 115VAC ± 10VAC, 50/60 Hz, 15 amps. The AC
outlet is recommended to be dedicated and unswitched, with a solid third-wire ground. (See
Power and Grounding Requirements" on Page
This eliminates interference from branch circuit motor noise or the like, and to prevent accidental
power-off. To avoid accidental power turn-off, Toshiba recommends that you do not use an On/Off
wall switch on this dedicated AC circuit.
For the Strata DK40i, a reserve power source (two customer-supplied 12VDC batteries) may be
connected to the system to serve as a power failure backup.
Clearance and Location
The minimum clearance requirements for the Strata DK40i Base and Expansion KSUs are shown
in
Figures 3-1
Top View
Front View
2"
4234
Figure 3-1
DK40i Base KSU Clearance
Requirements
Consider the following conditions when selecting a location for the KSU(s):
The location must be:
o
Dry and clean
o
Well ventilated
o
Well illuminated
o
Easily accessible
3-2