Table 4-7
Line Capacities and Universal Printed Circuit Board Slots
Lines and PCB Slots
Universal slots
CO lines – loop start
CO lines – ground start
DID lines (analog)
Tie lines (analog)
T1 (DS-1) lines each)
ISDN BRI (S/T or U) B channel lines
ISDN PRI (T) B channel lines
Squared System Maximum
(lines + stations)
1. There are four universal slots in the DK40i expansion unit.
2. All CO line capacities assume a PIOU, PIOUS, PEPU, RSSU, or RSIU is installed for RCTUBA/BB, RCTUC/D or RCTUE/
F, but no Caller ID RCIU2/RCIS PCBs.
3. Limits apply to analog DID and Tie lines, not T1 DID/Tie lines.
4. T1 lines can be loop start, ground start, Tie, or DID (maximum 24 lines per unit, any type or combination).
5. BRI lines provide CO line services, including Caller ID, DID and Direct Inward Lines (DIL).
6. PRI lines provide CO line services, including Caller ID, ANI, DID, Tie, POTS, FX and DIL.
Table 4-8
Station and Peripherals Capacities
Stations
Add-on modules (DADM)
Attendant consoles
DKT 2004-CT Cordless Telephones
DKT 2004-CT simultaneous calls
Door locks
Door phones (MDFB)
DSS consoles
ISDN BRI station circuits TE-1 and TA
1
(2B+D per circuit)
Handset OCA stations
Off-premise stations
2
PDIU-DS
RPCI-DI used for data + TAPI, per system
RPCI-DI used for TAPI only: per cabinet
RPCI-DI used for TAPI only: per system
Speaker OCA stations
Standard stations
Telephones – DKT
Telephones – EKT
1. ISDN BRI TE-1 and TA include ISDN telephones, modems, video conference interfaces, etc. Up to two stations (TE-1 and/or
TA) can connect to and share one BRI S-type circuit. Only one station can connect to a BRI U-type circuit.
2. Speaker OCA, PDIU and RPCI capacity is determined by 2B channel slot availability and power supply limits.
3. To install the maximum of 28 total DKTs and EKTs in the DK40i, up to 16 of the stations can be EKTs and at least 8 of the
stations must be DKTs.
4. Maximum capacity of DKT/EKT stations per DK424 cabinet is 62, less for EKT 2000, 3000 (Power Factor limitation).
Strata DK I&M
5/00
DK14
DK40i
RCTUA
1
0
4
2
4
12
0
12
0
12
0
12
0
0
0
12
0
0
4 lines +
12 lines +
16 lines +
4 stations
12 stations
16 stations
DK14
DK40i
8
12
0
0
8
28
8
9
2
3
6
9
0
3
0
10
8
28
2
20
7
24
2
8
24
2
N/A
N/A
2
8
24
8
28
2
20
3
8
28
3
0
16
DK424
RCTUBA/BB
RCTUC/D
6
12
36
2
2
16
48
144
2
2
16
40
136
3
3
16
40
136
3
3
16
40
136
4
0
48
144
5
5
8
16
16
6
0
47
141
48 lines +
144 lines +
48 stations
144 stations
DK424
RCTUA
RCTUBA/BB
RCTUC/D
12
40
0
2
32
80
9
9
4
5
9
12
3
4
8
16
32
80
32
80
31
79
32
80
32
40
32
80
32
80
24
72
4
4
32
80
240
4
4
32
80
240
DK424 Configuration
Features Capacities
RCTUE/F
54
2
2
200
2
2
200
3
3
200
3
3
200
4
4
192
5
5
16
6
6
188
200 lines +
200 stations
RCTUE/F
120
200
4
4
240
336
9
9
5
5
12
12
8
8
40
64
240
336
232
328
160
208
144
200
40
40
186
280
160
208
232
328
4
4
336
4
4
328
4-7

Advertisement