After mounting the DK424i cabinets, install the data cables. Then, install the bonding plate per
Figure
7-9.
Base Cabinet
C A
C A
C A
C A
C A
C A
Data Cables
Expansion
Cabinet
Data
Cable
Door
(shown open)
Expansion
Cabinet
Remote Cabinet Cable
feed through hole
Figure 7-9
Data Cables Shown in Cabinet Interior—Side View
Strata DK I&M
5/00
Cab 2 Cable
B
2
B
3
B
4
B
5
B
6
B
7
Left Side
Bonding Connection Plate
(required for all wall mount
To MDF
expansion cabinets)
DK424i Installation
Step 2: Mount Cabinets
Cable Guard
Screw
Cable Guard
PCB Cable
Front
5342
7-15