Operation Data - Toshiba RAS-10SKVR-E2 Service Manual

Air conditioner split type
Table of Contents

Advertisement

7-2. Operation Data

<Cooling>
Tempeature
condition(°C)
Indoor
Outdoor
27/19
35/-
<Heating>
Tempeature
condition(°C)
Indoor
Outdoor
20/-
7/6
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchaner path U bent.
(Thermistor themometer)
2. Connecting piping condition : 5 m
Standard
Heat exchanger
pressure
pipe temp.
P (MPa)
T1 (°C)
0.9 to 1.1
12 to 14
Standard
Heat exchanger
pressure
pipe temp.
P (MPa)
T1 (°C)
2.5 to 2.7
39 to 41
19
Indoor
fan mode
T2 (°C)
37 to 39
High
Indoor
fan mode
T2 (°C)
0 to 3
High
FILE NO. SVM-10029
Outdoor
Compressor
fan mode
revolution
(rps)
High
49
Outdoor
Compressor
fan mode
revolution
(rps)
High
60