Operation Data - Toshiba RAV-GM302ATP-E Service Manual

Table of Contents

Advertisement

3-2. Operation Data

RAV-GM302ATP-E
<Cooling>
Tempeature
condition(°C)
Indoor
Outdoor
27/19
35/-
<Heating>
Tempeature
condition(°C)
Indoor
Outdoor
20/-
7/6
RAV-GM402ATP-E
<Cooling>
Tempeature
condition(°C)
Indoor
Outdoor
27/19
35/-
<Heating>
Tempeature
condition(°C)
Indoor
Outdoor
7/6
20/-
Heat exchanger pipe
Standard
pressure
P (MPa)
TC (°C) TS (°C)
0.9 to 1.1
13 to 15 13 to 15
Standard
Heat exchanger
pipe temp.
pressure
P (MPa)
TC (°C) TS (°C)
2.5 to 2.7 35 to 37
5 to 6
Standard
Heat exchanger
pipe temp.
pressure
P (MPa)
TC (°C) TS (°C)
0.9 to 1.1
11 to 13 11 to 13
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
TC (°C) TS (°C)
2.5 to 2.6
35 to 42
4 to 6
- 23 -
Indoor
temp.
fan mode
TE (°C)
37 to 41
High
Indoor
fan mode
TE (°C)
High
3 to 5
Indoor
fan mode
TE (°C)
39 to 42
High
Indoor
fan mode
TE (°C)
High
3 to 5
Outdoor
Compressor
fan mode
revolution
(rps)
High
46
Outdoor
Compressor
fan mode
revolution
(rps)
High
74
Outdoor
Compressor
fan mode
revolution
(rps)
High
51
Outdoor
Compressor
fan mode
revolution
(rps)
High
53