11-9-3. Indoor Unit (Other Parts)
No.
Part name
1
Room temp. (TA) sensor
Heat exchanger (TC) sensor
2
Remote controller
3
Louver motor
MP24Z3T
4
Indoor fan motor
11-9-4. Outdoor Unit
No.
Part name
1
Compressor
(Model : DA89X1C-23FZ2)
2
Outdoor fan motor
(Model : ICF-140-43-4R)
3
4-way valve coil
(Model : STF)
4
Pulse motor valve coil
(Model : CAM-MD12TCTH-2)
5
Outdoor temperature sensor
(TO), discharge temperature
sensor (TD), suction
temperature sensor (TS),
outdoor heat exchanger
temperature sensor (TE)
Disconnect the connector and measure the resistance value with tester.
(Normal temp.)
Temperature
Sensor
TA, TC (kΩ)
Refer to 11-5-1. (5).
Measure the resistance value of each winding coil by using the tester.
(Under normal temp. 25°C)
White
1
1
Yellow
2
2
Yellow
3
3
Yellow
4
4
Yellow
5
5
Refer to 11-5-1. (3) and (4).
Measure the resistance value of each winding by using the tester.
Red
White
Black
Measure the resistance value of winding by using the tester.
Red
White
Black
Measure the resistance value of winding by using the tester.
Measure the resistance value of winding by using the tester.
W
1
COM
6
GR
O
3
Y
R BL
COM
2
5
Disconnect the connector, and measure resistance value with the tester.
(Normal temperature)
Temperature
Sensor
TD (kΩ )
TO,TS,TE (kΩ )
80
FILE NO. SVM-10029
Checking procedure
10°C
20°C
25°C
20.7
12.6
10.0
Position
1 to 2
1 to 3
1 to 4
1 to 5
Checking procedure
Position
Red - White
White - Black
Black - Red
Position
Red - White
White - Black
Black- Red
Resistance value
1435 ± 144Ω
Position
Gray - White
Gray - Orange
Red- Yellow
Red- Blue
4
10°C
20°C
25°C
100
64
50
20.7
12.6
10.0
30°C
40°C
7.9
4.5
Resistance value
250 ± 20Ω
Resistance value
DA89X1C-1F-23FZ2
1.04 to 1.16Ω
Under 20ºC
Resistance value
20 to 22Ω
20 to 22Ω
20 to 22Ω
Under 20°C
Resistance value
43 to 49Ω
43 to 49Ω
43 to 49Ω
43 to 49Ω
Under 20°C
30°C
40°C
50°C
41
27
18
7.9
4.5