Operation Data - Toshiba RAS-10YKV-E Service Manual

Split type
Hide thumbs Also See for RAS-10YKV-E:
Table of Contents

Advertisement

6-2. Operation Data

<Cooling>
Temperature
condition (°C)
Indoor
Outdoor
27/19
35/–
<Heating>
Temperature
condition (°C)
Indoor
Outdoor
20/–
7/6
NOTES :
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
(2) Connecting piping condition : 5 m
More user manuals on
Standard
Model name
pressure
P (MPa)
10YKV-E
0,8 to 1,0
13YKV-E
0,8 to 1,0
Standard
Model name
pressure
P (MPa)
10YKV-E
3,5 to 3,7
13YKV-E
2,5 to 2,7
ManualsBase.com
Heat exchanger
pipe temp.
Indoor fan
mode
T1 (°C)
T2 (°C)
9 to 11
42 to 44
High
8 to 10
46 to 48
High
Heat exchanger
pipe temp.
Indoor fan
mode
T1 (°C)
T2 (°C)
42 to 44
2 to 4
High
50 to 52
0 to 3
High
– 20 –
Compressor
Outdoor fan
revolution
mode
(rps)
High
56
High
85
Compressor
Outdoor fan
revolution
mode
(rps)
High
70
High
97

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-10yav-eRas-13ykv-eRas-13yav-e

Table of Contents