6-2. Operation Data
<Cooling>
Temperature
condition (°C)
Indoor
Outdoor
27/19
35/–
<Heating>
Temperature
condition (°C)
Indoor
Outdoor
20/–
7/6
NOTES :
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
(2) Connecting piping condition : 5 m
More user manuals on
Standard
Model name
pressure
P (MPa)
10YKV-E
0,8 to 1,0
13YKV-E
0,8 to 1,0
Standard
Model name
pressure
P (MPa)
10YKV-E
3,5 to 3,7
13YKV-E
2,5 to 2,7
ManualsBase.com
Heat exchanger
pipe temp.
Indoor fan
mode
T1 (°C)
T2 (°C)
9 to 11
42 to 44
High
8 to 10
46 to 48
High
Heat exchanger
pipe temp.
Indoor fan
mode
T1 (°C)
T2 (°C)
42 to 44
2 to 4
High
50 to 52
0 to 3
High
– 20 –
Compressor
Outdoor fan
revolution
mode
(rps)
High
56
High
85
Compressor
Outdoor fan
revolution
mode
(rps)
High
70
High
97