Make sure the rover
antenna has the best pos-
sible view of the sky at all
times during the survey.
This should result in #Sats
continuously greater than
4 and PDOP continuously
less than 4.
The Obs. Range field is
irrelevant to the Stop & Go
mode and for this reason
is left blank.
50

Data Collection

9. Walk to the 1st point you want to survey. Be careful not to
mask the antenna as this might cause loss of satellite sig-
nals.
10.Press the LOG key (not the on-screen Log button). The
Survey Settings screen is displayed allowing you to change
the following parameters:
• Site ID and Site Description: Change these two fields if
required.
• Antenna Height: New height of the rover antenna now
located on top of the pole.
• Initialize: Check that <None> is now selected
• Time on Site: Enter the occupation time needed on each
point that you will survey (typically 15 seconds).
11.While holding the pole stationary above the point, tap Log
on the screen. The receiver then displays the screen below
left.
12.Wait until Remain=00:00:00. The receiver then displays
the screen below right.