V3-E3B SERIES, V3-E3CB SERIES, V3-E3BG SERIES, WSM

[6] CHECK POINT OF EVERY 1000 HOURS

Checking Valve Clearance
IMPORTANT
• Valve clearance must be checked and adjusted when engine
is cold.
1. Remove the injection pipes.
(V3800DI-T-E3B, V3800DI-T-E3CB, V3800DI-T-E3BG only)
2. Remove the head cover.
3. Set the No.1 piston at the compression top dead center.
4. Slightly push the rocker arm by your finger.
(Valve bridge height adjustable type only)
5. Tighten the valve bridge height adjusting screw (1) slowly until
you feel the screw touch the top of valve stem.
(Valve bridge height adjustable type only)
6. Tighten the lock nut (2).
(Valve bridge height adjustable type only)
7. Adjust the valve clearance with feeler gauge.
8. Tighten the lock nut (4).
Valve clearance
Factory spec.
NOTE
• After adjusting, tighten the lock nut (4) securely.
Valve arrangement
Adjustment cylinder
Location of piston
When No.1 piston is at
compression top dead center
When No.1 piston is at
overlap position
Tightening torque
Cylinder head cover screw
Tightening torque
Injection pipe retaining nut
(1) Valve Bridge Height Adjusting Screw
(2) Lock Nut
(3) Adjusting Screw
(4) Lock Nut
G-18
G GENERAL
0.23 to 0.27 mm
0.0091 to 0.010 in.
IN.
1st
2nd
3rd
4th
1st
2nd
3rd
4th
6.9 to 11.2 N·m
0.70 to 1.15 kgf·m
5.1 to 8.31 lbf·ft
23 to 36 N·m
2.3 to 3.7 kgf·m
17 to 26 lbf·ft
[A] V3600-E3B, V3600-T-E3B,
V3600-E3CB, V3600-T-E3CB,
V3300-E3BG, V3600-T-E3BG
[B] V3800DI-T-E3B, V3800DI-T-E3CB,
V3800DI-T-E3BG
EX
W1037215