Check Points Of Every 1000 Hours - Kubota WG972-E2 Workshop Manual

Gasoline, lpg engine
Table of Contents

Advertisement

WG972-E2, DF972-E2, WSM

[6] CHECK POINTS OF EVERY 1000 HOURS

Replacing the Spark Plug
1. Disconnect the spark plug cap (1).
2. Remove the spark plug.
3. Replace the new spark plug.
Tightening torque
Spark plug
(1) Spark Plug Cap
Checking the Hot Water Hoses (DF972-E2)
1. Check the hot water hoses (1) for damage.
2. If the hot water hose is damaged, replace it.
(1) Hot Water Hoses to Vaporizer
Checking the Vacuum Lock Hoses (DF972-E2)
1. Check the vacuum lock hose (1) for damage.
2. If the hose is damaged, replace it.
(1) Vacuum Lock Hoses
Draining Tar (Vaporizer for DF972-E2)
1. Run the engine until it is warmed up.
2. The shut off valve is shut and the engine is stopped naturally.
3. Place an oil pan underneath the drain port.
4. Remove the drain plug (4), and drain tar.
5. Tighten the plug.
NOTE
• Apply a liquid gasket (Three Bond 1104 or equivalent) to the
thread of the plug.
(1) Vaporizer
(2) Water Hose
(3) Wrench
G-14
G GENERAL
19.6 to 24.5 N·m
2.0 to 2.5 kgf·m
14.5 to 18.1 ft-lbs
W1037215
W1037526
W1055412
(4) Drain Plug
(5) Liquid Gasket
(6) Joint
W1037642
KiSC issued 01, 2006 A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Df972-e2