Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
HOT GAS VALVE SOLENOID
Refer to page 4-12 for the procedure for servic-
ing the hot gas valve solenoid.
1.
Unplug ice maker or disconnect power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter test leads to the pins
of the hot gas valve solenoid 2-wire con-
nector. The meter should indicate between
240 and 300 Ω.
WARNING
Electrical Shock Hazard
MASTER SWITCH
Refer to page 4-14 for the procedure for servic-
ing the master switch.
1.
Unplug ice maker or disconnect power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Disconnect the wires from the terminals of
the master switch.
4.
Touch the ohmmeter test leads to the
following master switch terminals (the ter-
minal numbers are on the side of the
case). When the switch is in the indicated
position, as shown on the cover, the meter
should read:
Centered Position: All connections are an
open circuit (infinite):
Ice Position:
Pins 1 and 2 = closed circuit (0 Ω).
Pins 4 and 5 = closed circuit (0 Ω).
Wash Position:
Pins 2 and 3 = closed circuit (0 Ω).
5-3
1 OR
4 BK
2 BR
5 RD
3 OR
6 N/C