11. Remove the wire connectors from the
relay and the overload protector.
12. Pull the relay and the overload protector
from the compressor pins.
13. Access the sealed system and discharge
the refrigerant into an approved recovery
system.
14. Cut the suction and discharge lines.
15. Cut the filter/drier (see the photo at the top
of the next column) from the system (do
not use a torch to remove the filter/drier).
Discharge Line
Suction Line
Overload
Protector
Wire
Wire
Relay
4-21
16. Remove the four compressor mounting
screws from the rubber isolators and re-
move the compressor from the unit.
Compressor Screws
(1 Of 4)
Filter/Drier