Function group t.5 - Cup lift
t.5 - cup lift
next
upper_switch
= OFF
lower_switch
= OFF
key_up
= OFF
key_down
= OFF
cup_lift
cup_lift
*
up
down
Function group t.6 - Dosing
t.6 - grinder dose
next
mild dose
= 81
medium dose
= 90
strong dose
= 99
mild
medium
strong
value
value
value
up
down
test
Function group t.7 - Dreg counter
t.7 - dreg counter
next
max dreg counter
= 13
current dreg counter = 9
value
value
up
down
Saeco International Group
upper_switch:
lower_switch:
key_up:
key_down:
cup_lift up:
cup_lift down:
*:
mild dose
medium dose
strong dose
mild
medium
strong
value up:
value down:
value test:
max dreg counter:
current dreg count
value up:
value down:
*
*:
05 SERVICE MODALITY
ON - Microswitch cup lift (top end
position)
ON - Microswitch cup lift (bottom end
position)
ON - Cup lift sensor UP activated
ON - Cup lift sensor DOWN activated
Cup lift moves upwards
Cup lift moves downwards
no function
= medium dose -10% (fi x)
Range 60 - 150 (value up/down)
= medium dose +10% (fi x)
Setting for the dosing quantity test
Setting for the dosing quantity test
Setting for the dosing quantity test
Brewing unit moves to original posi-
tion
Brewing unit moves to brewing posi-
tion
Stop brewing unit
Maximum number of cycles until
"Empty dreg drawer" message
appears
Running dreg counter
increase the number of cycles
reduce the number of cycles
no function